These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
Product Specifications:
Item | Bolt On Circuit Breaker |
Ac Voltage Rating | 277/480 VAC |
Actuator | Toggle |
Amps | 40 |
Circuit Breaker Type | Shunt Trip |
Current Rating | 40A |
Dc Voltage Rating | Not Rated |
Depth | 4.05" |
Frame Size | 125A |
Length | 5.66" |
Max. Air Rating | 18kA |
Max. Operating Temp. | 104 Deg. F |
Max. Wire Size | 2/0 AWG |
Min. Wire Size | 14 AWG |
Mounting Style | Bolt-On |
Number Of Poles | 3 |
Product Datasheet | square-d-edb34040sa.pdf |
Terminal Connection | Lug |
Trip Unit Rating | 1800A |
Type | Shunt Trip |
Use With | Square D NF Panelboards |
Voltage Rating | 277V/480V AC |
Width | 3.92" |
Wire Size | 12 AWG (Al), 14 AWG (Cu) |
Shipping Info:
Ship weight (kg) | 1.73 |
Ship height (cm) | 10.29 |
Ship length (cm) | 14.38 |
Ship width (cm) | 9.96 |
HS code | 8536200020 |
Product Details:
Square D EDB34040SA circuit breaker is utilised in electrical systems to safeguard against excessive current, preventing damage to equipment and potential hazards. It is used in panel boards, switchboards and distribution boards, enhancing electrical safety in diverse environments. This circuit breaker has a current rating of 40A and is suitable for three-phase systems. It features a shunt trip mechanism, allowing for remote operation and enhancing safety by quickly tripping the circuit. This breaker is compatible with Square D NF panelboards and is mounted using a bolt-on style for secure installation. It comes with a maximum interrupting rating of 18kA at 277 / 480VAC. This circuit breaker has a maximum temperature of 104 degrees F and features a lug terminal connection type to ensure a secure & reliable attachment of wires to the circuit breaker.
Frequently Asked Questions:
Q. What is a 3-pole circuit breaker?
A. A 3-pole circuit breaker has three separate switching mechanisms or poles that can simultaneously disconnect all three phases of a three-phase electrical system. It is used in systems with multiple phases to ensure balanced protection.
Q. What is the current rating of this Square D EDB34040SA circuit breaker?
A. This circuit breaker is designed to handle a maximum continuous current flow of up to 40A without tripping.
Q. How to maintain this EDB34040SA circuit breaker?
A.
- Visually inspect the circuit breaker for damage or discolouration.
- Keep the breaker and its surroundings clean to prevent overheating.
- Exercise the breaker manually to prevent internal components from stagnating.
- Test the breaker's functionality using its test button periodically.
- Inspect wires for wear, damage or loose connections and address issues promptly.
- Check and ensure that all labels and markings on the breaker are legible.
- Monitor load balance in three-phase systems to prevent premature wear.
Documentation:
Product Variants
Product | Model | Price | |
---|---|---|---|
EDB14025 | €€121.97 | ||
EDB14030EPD | €€1,068.73 | ||
EDB14050 | €€133.73 | ||
EDB24125 | €€1,674.42 | ||
EDB14035 | €€121.97 | ||
EDB14045 | €€261.78 | ||
EDB34015SA | €€1,478.68 |
Explore Products
- CONTINENTAL 4/BX108 Banded Cogged V-Belt, 4 Ribs, 111 Inch Outside Length, 2 41/64 Inch Top Width
- EATON HCUE300D7N12 Active Harmonic Correction Unit With a Digital Interface Module, 8 kW Power Rating
- APPLETON ELECTRIC CJPS1715048 Pulse Start Metal Halide, 175W
- APEX-TOOLS 324-1X-5PK Power Bit 4F-5R Slotted 1/4 Shank PK5
- GRAINGER 18F.375X1.125-12 Carbon Steel Rectangular Bar, 0.38 Inch Thick, 1 1/8 Inch X 12 Inch Nominal Size
- T&S B-0133-ADF06-B Pre-Rinse Faucet, Spring Action, Wall Mount, 8 Inch Centers
- Stafford Mfg 2SM035R Shaft Collar, 2 Piece Split, 35mm I.D., M8 Set Screw
- TITAN FASTENERS NGBGARW-4
Explore More
- HEDLAND
- KEYSHAFT
- THERMO FISHER SCIENTIFIC
- KMC CONTROLS
- ABLOY
- Shelf Brackets and Supports
- Nuisance Dust and Procedural Masks
- Wave Washers
- Common Nails
- Chemical Metering Pump Repair Parts
- BIG BILL Westex Ultrasoft Flame Resistant Coveralls
- Krytox GPL 227 Series Anti Corrosion Grease
- DESTACO 334-M Series Pull Action Latch Clamps
- MSA Ultra-Twin Full Facepiece Respirators, Hycar
- PARKER Hex Coupling, Carbon Steel
- TB WOODS QD Bushings
- HALLOWELL Bulk Rack Shelfs
- KESON Chalk Line Reels
- BRYANT Locking Receptacles
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.