These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
SPEAKMAN SE-950 Test Kit, Shower And Eyewash
Get it by Tuesday, Mar 4
Payment
Delivery
Product Specifications:
Item | Test Kit |
Shipping Info:
Ship weight (kg) | 3.6 |
Ship height (cm) | 31.75 |
Ship length (cm) | 38.74 |
Ship width (cm) | 38.74 |
HS code | 3926909985 |
Country of Origin | CN |
Product Details:
Speakmanmanufactures plumbing products and safety equipment for use in commercial facilities and manufacturing & chemical industries. Speakman SE-950 shower & eyewash test kit is used to examine the performance of emergency safety showers and eyewashes. Emergency eyewash & shower stations are used primarily in chemical applications to flush away chemicals & irritants from a worker's body, face or eyes and prevent injuries / accidents.
Features:
- Speakman SE-950 shower & eyewash test kit contains an assortment of tools like bucket and lid, funnel sleeve, attachment ring, handle and eyewash tester.
- The 5 gallon / 20-litre white bucket & lid has a plastic construction and collects the dispensed water from shower stations.
- The funnel sleeve, made of vinyl, channels the water from shower heads into the bucket.
- The steel attachment ring & PVC handle connect the funnel sleeve to the showerhead and control the water flow.
- The eyewash tester made of plastic acts like a gauge to test the height, flow rate & other parameters of water flow in eyewash stations.
Compatible Accessories:
- Speakman Drench Showers: They are used for emergency full body rinsing of a worker exposed to hazardous chemicals.
- Speakman Eye Wash Stations: They are used to remove irritants or chemicals from the eyes of workers for preventing eye injuries.
- Speakman Combination Units: These units provide both emergency shower systems and eye & face wash systems at a single location for ease of access in emergencies and quick maintenance.
Standards and Approvals:
- ANSI / ISEA Z358.1
- OSHA
Frequently Asked Questions:
Q. How often should emergency shower & eyewash stations be tested?
A. Users should run these emergency, shower & eyewash units weekly for testing the water flow. Full inspection may be done periodically or annually according to local safety standards & guidelines.
Q. What are the points to be noted while installing emergency shower & eyewash stations?
- A.
- Users should install the shower & eyewash stations in a well-lit location with a highly visible sign. The path towards these stations must be obstruction free to save time & prevent accidents.
- They must be located within 10 seconds from a hazardous application and immediately adjacent to the hazards involving strong acids or caustics.
- The units should start supplying water within one second after actuation. The supplied water should have a tepid temperature ranging from 16 to 38 degrees C (60 to 100 degrees F).
Q. What steps should workers follow if they are exposed to hazardous chemicals?
- A.
- Use an emergency shower or eyewash immediately if your skin or eyes are exposed to hazardous chemicals or irritants. Delayed washing may result in irreparable tissue or eye damage.
- In case of exposure to the eyes, flush the eyes for a minimum of 15 minutes. The eyes should be kept open and rotated in all directions for removing contamination thoroughly.
- In case of exposure to the skin, flush the exposed body part with a large quantity of water for a minimum of 15 minutes. The user / worker should remove contaminated clothing, jewellery, and shoes for a thorough cleaning.
Explore Products
- STEARNS BRAKES 1087081U0HQF
- BRADY 23541 Number Tag Brass Series Hwr 126-150 Pk25
- DAYTON MH2LEB924 Cylinder Body
- COXREELS 1195-2032-C Hand Crank Hose Reel, 2 Inch Inner Dia., 115 Feet Length
- THOMAS & BETTS 54511PFM20PH Copper Two Way Splice, Wire Size 3/0 AWG, Pack Of 10
- MAIN FILTER INC. MF0714494 1263061 Interchange Hydraulic Filter, Glass, 10 Micron Rating, Viton Seal, 19.01 Inch Height
- CONEX BANNINGER EE-5020401S Slow Bend, 15mm Size, 10 Pack
- STARRETT-UK DV8229 KLIX24-N I-Beam Level, Aluminium, 24 Inch Size
Explore More
- CHAPIN
- HEDLAND
- KEYSHAFT
- SOLAIRA
- DDS
- Hose Clamp Assortments
- Single Pressure Controls
- Borescope
- Enclosure Air Conditioners
- Cylinder Hand Truck Accessories
- CONDOR General Purpose Gloves, Yellow/Black, Abrasion Level 3
- ANSELL Class 00 Electrical Gloves, 14 Inch, Black
- DMS HICS 2014 Hospital Incident Command Vest Kits
- BALLYMORE Lock N Stock Ladders
- Krytox 250AD Series Aerospace Extreme Pressure Grade Fluorinated Grease
- COOPER B-LINE Horizontal Adjustable Kits
- LUMAPRO Headlamps
- ANSELL 70-225 Hyflex Reversible Cut Resistant Gloves
- GATES Ag Master Spray Chemical Hoses
- WATTS SST20 Series Compression Fittings
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.