These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
FINISH THOMPSON DB10V-T-M207 Pump Magnetic Drive 1 1/2 Hp 208-230/460v
Get it by Tuesday, Feb 25
Payment
Delivery
Product Specifications:
Item | Magnetic Drive Pump |
Bearing Type | Thrust & Radial |
Bearings | Thrust & Radial |
Design | Centrifugal |
Full Load Amps | 4.25-3.90/1.95 |
Gasket | Viton |
Gasket Material | Viton |
Gpm @ 1 Ft. Of Head | 95 GPM |
Gpm Of Water @ 15 Ft. Of Head | 95 |
Gpm Of Water @ 18 Ft. Of Head | 94 |
Gpm Of Water @ 24 Ft. Of Head | 85 |
Gpm Of Water @ 3 Ft. Of Head | 95 |
Gpm Of Water @ 40 Ft. Of Head | 66 |
Gpm Of Water @ 50 Ft. Of Head | 38 |
Gpm Of Water @ 6 Ft. Of Head | 95 GPM |
Gpm Of Water @ 9 Ft. Of Head | 95 |
Height | 8 19/64" |
Housing | PVDF |
Housing Material | PVDF |
Hp | 1.5 |
Impeller | PVDF w/PTFE Bushing |
Impeller Material | PVDF w/PTFE Bushing |
Inlet | 1-1/2 FNPT |
Length | 17 19/64" |
Max. Head | 52 ft. |
Max. Specific Gravity | 1.5 |
Max. Viscosity | 100 CPS |
Motor Enclosure | TEFC |
Motor Type | Induction |
Mounting | Horizontal |
Mounting Orientation | Horizontal |
Operating Pressure | 32 PSI |
Outlet | 1-1/2 MNPT |
Temp (f) @ 0 Psig | 220 |
Temp (f) @ 10 Psig | 220 |
Temp (f) @ 20 Psig | 220 |
Temp (f) @ 30 Psig | 220°F |
Type | Straight |
Voltage | 208-230/460 |
Width | 7.5" |
Shipping Info:
Ship weight (kg) | 22.73 |
Ship height (cm) | 33.53 |
Ship length (cm) | 56.9 |
Ship width (cm) | 32.26 |
HS code | 8413810040 |
Country of Origin | US |
Product Details:
Finish Thompson DB10V-T-M207 magnetic drive pump is used for transferring corrosive or hazardous fluids. Its magnetic drive design eliminates the need for traditional seals, preventing leaks and ensuring environmental safety. This magnetic drive pump is ideal for chemical manufacturing, pharmaceutical production, wastewater treatment and laboratory settings.
Features:
- It features a durable PVDF housing, ensuring corrosion resistance in handling corrosive liquids.
- This magnetic drive pump has a maximum flow rate of 95 gpm.
- It comes with a 1-1/2 hp motor, providing sufficient power for efficient fluid transfer.
- This magnetic drive pump offers a maximum discharge pressure of 32 psi.
- It is equipped with a Viton gasket, ensuring reliable sealing.
- This pump features a totally enclosed fan-cooled enclosure for efficient heat dissipation and protection from dust & moisture.
- It is designed with a radial and thrust bearing, enhancing stability and longevity in operation.
Compatible Accessories:
- Tridon 6812 Hose Clamp: It is designed to securely fasten hoses onto pipes or fittings, ensuring leak-free connections.
Frequently Asked Questions:
Q. What is the difference between a vacuum pump and a centrifugal pump?
A. As compared to vacuum pumps, centrifugal water pumps are easier to install and when a repair is required, the parts can be taken apart and restarted within a short period of time.
Q. How to maintain this magnetic drive pump?
A.
- Visually inspect the pump seasonally to ensure there is no build-up of any kind inside the unit.
- Clean the inlet tube if no water is entering the reservoir.
- If there is a proper amount of water in the reservoir, the float may be stuck due to dirt / algae formation. Flush the reservoir with warm water and a mild soap or detergent.
- Inspect the discharge tubing to ensure it is clear, making sure the tubing end is not plugged.
- Also make sure the check valve is not clogged. In case it is, unplug the pump and remove the fitting. Clean with mild soap or detergent.
Q. What types of fluids can magnetic drive pumps handle?
A. Magnetic drive pumps are designed to handle a wide range of fluids, including acids, alkalis, solvents, slurries, deionised water and other corrosive or hazardous liquids.
Explore Products
- BRADY 7219-4-PK Pipe Marker, Potable Water, Green, White, Fits 3/4 to 2 3/8 Inch Size Pipe OD
- VOLKEL 44546 Refill, From Stainless Steel, BSW 7/16 x 14 - 2.5D Size
- NIBCO I057000 Long Turn DWV Elbow, 1-1/2 Inch Size, ABS
- MERSEN FERRAZ Z301023 A130UD70TTI315 Fuse, 315A
- DAYTON 10E036 Exhaust Fan Venturi Frame 24 x 24 Galvanised
- HAMMOND 1489P12 Pushbutton Enclosure, 12 Holes, 30mm, 13 x 10 x 6 Inch Size, Wall Mount, Carbon Steel
- VERMONT GAGE 141109720 Class X Go Pin Gauge, 0.0972 Inch Dia, 0.00004 Inch Tolerance
- DAYTON 4YU95 Downblast Vent Belt Drive 14-3/4 In
Explore More
- AEROQUIP
- KEYSHAFT
- TRAMEX
- ARROW MIXING PRODUCTS
- JONES STEPHENS
- Hazardous Location Control Station Switches
- Dry Baths
- Bottle Caps
- Magnetic Starters with Thermal Overload
- Pipe and Tube Clamps
- ANSELL 47-200 Activarmr White Green Nitrile Coated Gloves
- VIEGA PROPRESS Reducers, Stainless Steel, Press x FTG, FKM
- ASSOCIATED SPRING RAYMOND CU420 Gas Springs
- ASSOCIATED SPRING RAYMOND TU 750 Gas Springs
- GUARDIAN EQUIPMENT Roof Anchor
- SALISBURY Connector End Line Hose
- BALDWIN FILTERS In-Line Fuel Filters
- PARKER A-LOK Series, Compression Tube Fittings
- ENERPAC Swing Clamp Arms
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.