These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
ELOBAU 117614E1-10 Safety Sensor, With Built In Relay
Payment Options Available
Delivery Options Available
Product Specifications:
Item | Sensor |
Actuation Frequency | 18000/1 h |
Actuation Type | Front |
Air Pressure | 860 to 1060 hPa |
Assured Switch Off Distance | 21 mm |
Assured Switching Distance | 3 mm |
Cable Color | Silver Grey |
Cable Length | 1 m |
Cable Material | TPE |
Cannot Be Mounted Flush | No |
Continuous Shock Resistance | 10 g/ 16 ms |
Current Consumption | 100 mA |
Degree Of Pollution | 2 |
Delta Tmax | 0.5 Deg. C/min. |
Edm/start Input | No |
Free Zone | 25 mm |
Fuse Control Output | 3A |
Fuse Operating Current | 0.5A |
Fuse Safety Output | 3A |
Housing Color | Silver |
Housing Design | Rectangular |
Housing Material | PBT |
Ip Rating | Ip67 |
Led Display | Single Coloured |
Max. Cable Temp. Range, Fixed Installation | 55 Deg. C |
Max. Cable Temp. Range, Moving | 55 Deg. C |
Max. No. Operating Cycles At 0.5a Switching Current (ohmic Load) | 1000000 |
Max. No. Operating Cycles At 2.5a Switching Current (ohmic Load) | 230000 |
Max. Operating Speed | 0.1 m/min. |
Max. Operating Temp. | 55 Deg. C |
Max. Operating Voltage | 253V AC |
Max. Storage Temp. | 55 Deg. C |
Max. Switching Current At Control Output | 3A |
Max. Switching Power At Control Output | 750VA, 90W |
Max. Switching Power At Safety Output | 750VA, 90W |
Max. Switching Voltage At Control Output | 250V AC/ 30V DC |
Max. Switching Voltage At Safety Output | 250V AC/ 30V DC |
Min. Cable Temp. Range, Moving | -25 Deg. |
Min. Cable Temperature Range, Fixed Installation | -25 Deg. C |
Min. Operating Temp. | -25 Deg. C |
Min. Operating Voltage | 207V AC |
Min. Storage Temp. | -25 Deg. C |
Min. Switching Current At Control Output | 0.01A, 3A |
Min. Switching Current At Safety Output | 0.1A |
Min. Switching Power At Control Output | 0.12W |
Min. Switching Power At Safety Output | 0.5W |
Min. Switching Voltage At Control Output | 12V AC/DC |
Min. Switching Voltage At Safety Output | 5V DC |
Minimum Installation Distance (between Two Sensors) | 50 mm |
Minimum Switching Distance | 0.5 mm |
Mounting Type | Screw |
Number Of Relay Control Output | 1 |
Number Of Relay Safety Output | 1 |
Number Of Strands | 5 |
Overvoltage | Category III |
Power Consumption | 23VA |
Protection Class | Class III |
Readiness Delay | 350 ms |
Relative Humidity | 5% to 85 % |
Shock Resistance | 30 g/ 11 ms |
Size | 120 mm x 40 mm x 40 mm |
Switching Principle | Magnetic |
Technology | Reed |
Utilization Category | 15-AC/-13-DC |
Vibration Resistance | 10 Hz to 55 Hz |
Wire Cross Section | 0.75 Sq. mm |