Eaton BR4242B400R | Main Circuit Breaker Loadcenter, 400A, 42 Circuits, Single-Phase
raptor logo

Strictly Necessary Cookies

Always Active

These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.

In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.

Advertising

These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.

recommendations

These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.

Functional

These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.

analysis

These cookies help us improve our website by collecting and reporting information on how you use it.

We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.
EATON BR4242B400R Main Circuit Breaker Loadcenter, 400A, 42 Circuits, Single-Phase | BJ7TCY

EATON BR4242B400R Main Circuit Breaker Loadcenter, 400A, 42 Circuits, Single-Phase

Item: BJ7TCY Model: BR4242B400R
Limited Availability

Due to weight and dimension restrictions, please request a shipping quote

Add To Cart
Request a Quote

Payment Options Available

Delivery Options Available

Product Specifications:

ItemLoad Center

Shipping Info:

Ship weight (kg) 46.35
Ship height (cm)20.32
Ship length (cm)176.53
Ship width (cm)49.53
Country of OriginUS

Product Details:

Eaton BR4242B400R main circuit breaker load center is designed to distribute utility-supplied electricity throughout the building for feeding all branch circuits. The circuit breaker located in the load center protects each branch circuit.

Features:

  • This load center can protect against ground and arc faults by employing specialty or electronic circuit breakers.
  • It can be mounted in or against a wall.
  • The NEMA type 3R enclosure protects against rain, sleet & damage from external ice formation.

Compatible Accessories:

  • Eaton BR Circuit Breakers: These circuit breakers feature diagnostic trip codes for complex occurrences. Their short-body design maximises space inside the load center by adding wire-way and gutter space for easy installation.

Standards and Approvals:

  • UL
  • CSA
  • NEC

Frequently Asked Questions:

Q. How to install Eaton BR4242B400R load center?

A.

  • Remove the knockouts needed to install cable clamps or conduits.
  • To fasten the enclosure to the wall, align and level it with removable nails or screws inserted through keyholes at the top and bottom.
  • Place the enclosure between the studs.
  • Both sides of the enclosure are provided with 3/8-inch (17.1 mm) and 1/2-inch (12.7 mm) drywall scribe markings to aid when flush mounting.
  • Oval knockouts are provided on each side of the enclosure for mounting. Remove the knockout and insert a nail or screw through the oval opening.
  • Connect the main and neutral wires. Torque the wire pressure screws to the value indicated on the main label on the inside of the door.
  • Install BR branch circuit breakers by sliding the breaker's foot under the back pan rail and pushing the breaker onto the bus stab.
  • Connect the branch circuit wire to the circuit breaker's load end. Tighten the wire pressure screw to the torque value listed on the load centre enclosure.
  • Remove only the twist-outs that correspond to the corresponding breaker positions. Twist-outs can be removed by striking with a screwdriver and twisting back & forth with pliers.
  • The inner cover can be adjusted to fit snugly against breakers for flush mounting. Turn the two adjusting screws counter-clockwise to move the cover inward. Alternately, adjust each screw until the desired fit is achieved.

Q. Is a load center a panel?

A. A load center is also known as an electrical panel.

Q. Does a load center need a main breaker?

A. A load center can either be equipped with a main breaker or with a main lug only (MLO) design.

Product Variants

ProductModelPrice
EATON 3B4242ESN Main Breaker Loadcenter, Current Design, Main Circuit Breaker, 600 A, 24, Aluminum | BJ6NAK 3B4242ESN€11092.60
RFQ
EATON 3BR1224B100S Main Breaker Loadcenter, No Feed-Thru Lugs, Main Circuit Breaker, 100 A, C1, Aluminum | BJ6NBE 3BR1224B100S€€3,501.04
EATON 3BR1224BC100 Main Breaker Loadcenter, Main Circuit Breaker, 100 A, C1, Copper, Nema 1, 10 Kaic, Br | BJ6NBG 3BR1224BC100€€3,845.08
EATON 3BR1224BC100R Main Breaker Loadcenter, Main Circuit Breaker, 100 A, C1R, Copper, Nema 3R, 10 Kaic, Br | BJ6NBH 3BR1224BC100R€€4,571.14
EATON 3BR1224B100R Main Breaker Loadcenter, No Feed-Thru Lugs, Main Circuit Breaker, 100 A, C1R, Aluminum | BJ6NBJ 3BR1224B100R€€783.12
EATON 3BR1224B100 Main Breaker Loadcenter, No Feed-Thru Lugs, Main Circuit Breaker, 100 A, C1, Aluminum | BJ6NBK 3BR1224B100€€3,728.06
EATON 3BR1224H100 Main Breaker Loadcenter, High Aid, Main Break High Aid, 100 A, C1, Aluminum, Cover Included | BJ6NBQ 3BR1224H100€€4,989.47

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

EATON BR4242B400R Main Circuit Breaker Loadcenter, 400A, 42 Circuits, Single-Phase