These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
Product Specifications:
Item | Fuse |
Ac Voltage Rating | 600V |
Body Material | Melamine |
Body Style | Cylinderical |
Class | Class G |
Connection Type | Ferrule End x Ferrule End |
Current Rating | 15A |
Dc Voltage Rating | 170V |
Diameter | 7/16" |
Element | Dual |
For Fuse Block Series | BG, G, HPS |
Functionally Equal To | Ferraz/Gould AG1, Littlefuse SLC |
Fuse Amps | 15 |
Fuse Block Design | Rejection |
Indicating / Nonindicating | Nonindicating |
Interrupt Rating | 100kA at 600V AC, 10kA at 170V AC |
Length | 1 5/16" |
Mfr. Series | Bussmann SC, Littelfuse SLC, Mersen AG |
Product Datasheet | bussmann-sc-15.pdf |
Rejection / Nonrejection | Rejection |
Speed | Time Delay |
Visual Indication | Non Indicating |
Voltage Rating | 600VAC/170VDC |
Shipping Info:
Ship weight (kg) | 0.05 |
Ship height (cm) | 3.33 |
Ship length (cm) | 1.04 |
Ship width (cm) | 1.04 |
HS code | 8536100040 |
Country of Origin | MX |
Product Details:
Bussmann SC-15 fuse is used in electrical circuits, industrial machinery, control panels and motor circuits where a compact and reliable overcurrent protection solution is needed. This fuse safeguards electrical components and systems from overloads and short circuits.
Frequently Asked Questions:
Q. What factors should I consider while choosing a midget fuse?
A.
- Match the fuse's current rating with the circuit's requirements.
- Ensure that the fuse can handle the circuit's voltage level.
- Select a fuse with an interrupt rating suitable for potential fault currents.
- Choose between fast-acting and time-delay fuses based on circuit characteristics.
Q. How do you test a fuse without a fuse tester?
A. To test a fuse, use wire strippers to remove approximately an inch of insulation from both ends of the wire. Attach one wire end to a fuse terminal and the other wire end to the opposite terminal on the fuse. If the fuse is operational, the light bulb will illuminate. Conversely, if the fuse is defective, the light bulb will not light up.
Q. Can fuses be used over the years without any replacement?
A. Fuses deteriorate over time and will ultimately stop functioning. A fused-out condition doesn't invariably indicate equipment malfunction. However, refrain from persistent fuse replacement if it blows out immediately after replacement.
Q. What does Class SC in fuse mean?
A. Class SC fuses exhibit size-rejecting characteristics concerning their total length, effectively preventing over fusing situations.
Q. How do I install this fuse?
A.
- Align the fuse with the designated fuse holder or block.
- Insert the fuse pins into the corresponding slots or sockets.
- Rotate the fuse gently in the direction indicated by the bayonet design until it locks into place with a click.
- Ensure that the fuse is securely seated and cannot be pulled out easily.
- To remove the fuse, reverse the twisting motion and gently pull it out of the holder.
- Always ensure that the power is disconnected before installing or removing the fuse to prevent electrical hazards.
Q. What safety precautions should I take while using this Bussmann SC-15 fuse?
A.
- Use appropriate personal protective equipment (PPE) while handling electrical components.
- Consider the correct fuse type, voltage and current rating required for the application.
- Follow manufacturer's instructions for installation and replacement.
- Avoid exceeding the fuse's voltage or current ratings to prevent overheating and hazards.
- Regularly inspect and test the fuse to ensure proper functionality.
Q. How do I install this fuse?
A.
- Align the fuse with the designated fuse holder or block.
- Insert the fuse pins into the corresponding slots or sockets.
- Rotate the fuse gently in the direction indicated by the bayonet design until it locks into place with a click.
- Ensure that the fuse is securely seated and cannot be pulled out easily.
- To remove the fuse, reverse the twisting motion and gently pull it out of the holder.
- Always ensure that the power is disconnected before installing or removing the fuse to prevent electrical hazards.
Documentation:
Product Variants
Model | Body Style | Class | Current Rating | Element | Fuse Amps | Interrupt Rating | Length | Speed | Price | |
---|---|---|---|---|---|---|---|---|---|---|
SC-25 | Cylindrical | G | - | Dual | 25 | 100kA at 480VAC, 10kA at 300VDC | 1.625" | Time Delay | €€13.76 | |
SC-30 | Cylindrical | G | - | Dual | 30 | 100kA at 480VAC, 10kA at 300VDC | 1.625" | Time Delay | €€13.76 | |
SC-1 | Cylinderical | Class G | 1A | Single | 1 | 100kA at 600V AC, 10kA at 170V AC | 1 5/16" | Fast Acting | €€15.38 | |
SC-1-1/2 | Cylindrical | G | - | Single | 1.5 | 100kA at 600VAC, 10kA at 170VDC | 1 5/16" | Fast Acting | €€17.01 | |
SC-1/2 | Cylindrical | G | - | Single | 1/2 | 100kA at 600VAC, 10kA at 170VDC | 1 5/16" | Fast Acting | €€15.38 | |
SC-10 | Cylindrical | G | - | Dual | 10 | 100kA at 600VAC, 10kA at 170VDC | 1 5/16" | Time Delay | €€13.76 | |
SC-12 | Cylindrical | G | - | Dual | 12 | 100kA at 600VAC, 10kA at 170VDC | 1 5/16" | Time Delay | €€12.73 |
Explore Products
- EATON MD175E79ES Motor Drive Isolation Transformer, 3-Phase, Primary 480V, Secondary 480Y/277V, 175 KVA
- EATON XBPT25BU Terminal Block, Level-1, 800 VAC, 31A, 28 to 12 Awg, 26 to 12 Awg Wire, Din Rail Mount
- SMC VALVES SY50M-4-1A Cover Assembly
- DAYTON 4YFG7 Unit Bearing Motor 1/125hp 1550 Rpm 115v
- GRAINGER 5CRE6 Poly Tubing, 20 Inch Width, 1075 Ft Roll Length, Fda Compliant, 3 Inch Core Dia
- EDWARDS SIGNALING 435EX-8S1 Explosion Proof Bell, Vibrating, 8 Inch Size, 250VDC
- CASH VALVE GT11314546 Pusher Post, 1 Size, Type G60
- SMC VALVES VFS5000-S-04 Sub Plate, 1/2 Inch Size, Body Port
Explore More
- KEYSHAFT
- KWIKSET
- SWEEPEX
- TESTO
- JUNO LIGHTING GROUP
- Lab Circulator Accessories
- Negative Air Machine Accessories
- Threading Tools
- Air Cylinder Speed Controls
- Wire Wrap Tool Accessories
- ANSELL 11-818 Hyflex Ultralight Multi Purpose Gloves
- IRONCLAD Kong Cold Condition Waterproof Gloves
- ALLEGRO SAFETY Flexrist Wrist Supports
- HALLOWELL Pedestal Bench Top
- SUPER MET-AL Water Based Jumbo Auto Markers
- BUSSMANN Type S Series Specialty Fuses
- Krytox 250AC Series Aerospace Extreme Pressure Grade Fluorinated Grease
- ALLPAX Standard Hollow Punch Kits
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.