These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
YELLOW JACKET Plus II Charging Hoses
Yellow Jacket vacuum hoses transfer CFC, HFC and HCFC refrigerants to HVAC vacuum systems using vacuum pumps. These hoses & vacuum pump systems are ideal for medical, manufacturing, maintenance & repair and storage facilities.
Style | Model | Price (ex. VAT) | |
---|---|---|---|
A | 21660 | €46.60 | |
B | 21048 | €44.07 | |
C | 25985 | €268.00 | |
D | 22983 | €151.39 | |
E | 21983 | €115.73 | |
F | 22984 | €173.63 | |
B | 21672 | €52.87 | RFQ
|
B | 21272 | €52.87 | |
B | 21072 | €52.87 | RFQ
|
B | 21648 | €44.06 | |
B | 21248 | €44.02 | |
G | 21060 | €46.60 | |
H | 21260 | €46.60 | |
I | 22985 | €188.17 | |
J | 29985 | €233.08 | |
A | 29660 | €79.53 | |
H | 29260 | €79.53 | |
K | 29060 | €80.77 | |
L | 25986 | €297.37 | |
M | 22986 | €199.44 | |
N | 21985 | €134.37 | |
K | 14560 | €78.80 | |
O | 29983 | €220.03 |
Working Mechanism
- These hoses have flare style fittings on each ends for making connections.
- The hose's ends are connected to inlet / outlet ports of vacuum pumps on one end and to the HVAC system on the other end.
- The fittings are screwed onto the pump's & HVAC system's ports without additional tools.
- Yellow Jacket vacuum hoses have colour coded protective jackets to connect particular colour hose to selected inlet / outlet port, thereby preventing mismatching.
- Selected models having integrated ball valves regulate the refrigerant pressure with precision.
Features
- They have nylon permeation barrier for safely conducting CFC, HFC and HCFC type refrigerants.
- Their moisture layer / barrier provides resistance against moisture migration, thereby preventing refrigerant contamination.
- They have braided layer for preventing hose from breaking / cracking by excessive bending.
- Their outer rubber cover prevents liquids from penetrating inside the hose.
- They have flare fittings for enabling easy installation without additional tools.
- Selected models have compact ball valve ends for manually stoping the refrigerant flow through the hose in case of emergencies.
Compatible Accessories
- Manifold Gauge Sets: They are connected to vacuum gauges for checking the connected system's pressure.
Standards and Approvals
- UL
Frequently Asked Questions
What is the burst pressure rating of these hoses?
Yellow Jacket vacuum hoses are capable of operating under 3000 or 4000 PSI burst pressures.
Why are charging hoses angled?
These hoses have angled fittings to enable connection in tight spaces. Angled tips are ideal for both recharging and maintenance tasks.
How to check vacuum hoses?
Users must check for small tears and cracks at hose ends. The fitting's internal threads should be examined for wear and the hose should be checked for bulges indicating torn internal layers.
Are vacuum hoses universal?
Yes, vacuum systems have outlet holes that measure 2.5 inches in diameter. The screw-on fittings on these vacuum hoses can be easily installed on 2.5 inch diameter holes.
What are manifold gauges?
These gauges are used with vacuum hoses while recharging or repairing cooling systems. The vacuum hoses connect these gauges with the HVAC system to check both high & low refrigerant pressure for leak detection, measuring refrigerant volume and troubleshooting tasks.
What are low loss fittings?
These low loss, anti blowback fittings are used on Yellow Jacket vacuum hoses to trap the refrigerant inside the hose when disconnected. It prevents finger burns and the release of toxic refrigerants into the atmosphere.
We are here to help!
Looking for a part not listed here?
Explore More
- KEYSHAFT
- PROTEKTIVE PAK
- AFC CABLE SYSTEMS
- SURE FRAME
- DINNECTOR
- Prep and Hold Utensils
- Welding Cable Connectors
- Bench Buffers
- Appliance Hand Trucks
- Oil Filters / Lube Filters
- STARRETT Tilted Face Dial Test Indicator
- DESTACO 602 Series Straight Line Action Clamps
- PARKER 130 Series, Relief Valves
- TENNSCO Thin Profile Slotted Shelf
- COOPER B-LINE B234 Series Four Hole Left Hand Corner Gussets
- SPEARS VALVES CPVC Schedule 80 Fitting Unions, Socket x Fipt with Brass Thread Insert & EPDM O-ring Seal