These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
PARKER Thermostatic Expansion Valves
Thermostatic expansion valves control the flow of liquid refrigerant into an evaporator and keep air conditioning units running smoothly.
Style | Model | Connection | Item | Price (ex. VAT) | |
---|---|---|---|---|---|
A | HXCAE-3-ZX200 | - | Thermostatic Expansion Valve | €269.08 | |
A | HXAE-3-ZX200 B15 | - | Thermostatic Expansion Valve | €250.16 | |
B | TXV KIT | - | Valve | €867.78 | |
C | HXCAE-5-ZX200 | - | Thermostatic Expansion Valve | €326.74 | |
D | HXCAE-3-VX100H | - | Thermostatic Expansion Valve | €255.39 | |
C | HXAE-5-ZX200 | - | Thermostatic Expansion Valve | €297.33 | |
C | HXEA-3-ZX200 | - | Thermostatic Expansion Valve | €250.16 | |
E | HXCAE-5-VX100H | - | Thermostatic Expansion Valve | €307.23 | |
F | SCE-AA-VZ | Angle Solder | Thermostatic Expansion Valve | €290.32 | |
F | SCE-B-VZ | Angle Solder | Thermostatic Expansion Valve | €331.96 | |
F | SCE-A-VZ | Angle Solder | Thermostatic Expansion Valve | €279.93 | |
F | SCE-B-SZ | Angle Solder | Thermostatic Expansion Valve | €280.02 | |
G | CECSW | SAE Flare Angle | Thermostatic Expansion Valve | €249.41 | |
G | CEBJW | SAE Flare Angle | Thermostatic Expansion Valve | €218.28 | |
H | CASW | SAE Flare Angle | Thermostatic Expansion Valve | €203.97 | |
H | CASX35 | SAE Flare Angle | Thermostatic Expansion Valve | €203.97 | |
H | CCSW | SAE Flare Angle | Thermostatic Expansion Valve | €206.58 | |
H | CAVW | SAE Flare Angle | Thermostatic Expansion Valve | €210.90 | |
G | CEAVX35 | SAE Flare Angle | Thermostatic Expansion Valve | €243.66 | |
H | CCVW | SAE Flare Angle | Thermostatic Expansion Valve | €203.90 | |
H | CCJW | SAE Flare Angle | Thermostatic Expansion Valve | €203.97 | |
H | CCVX100 | SAE Flare Angle | Thermostatic Expansion Valve | €242.46 | |
G | CECJW | SAE Flare Angle | Thermostatic Expansion Valve | €245.10 | |
I | CECVX100 | SAE Flare Angle | Thermostatic Expansion Valve | €241.17 | |
J | CEBVX100 | SAE Flare Angle | Thermostatic Expansion Valve | €227.32 | |
H | CAAVW | SAE Flare Angle | Thermostatic Expansion Valve | €244.21 | |
H | CAAVX35 | SAE Flare Angle | Thermostatic Expansion Valve | €253.08 | |
I | CAJW | SAE Flare Angle | Thermostatic Expansion Valve | €233.56 | |
I | CEBVW | SAE Flare Angle | Thermostatic Expansion Valve | €249.35 | |
J | C-AA-JW | SAE Flare Angle | Thermostatic Expansion Valve | €244.21 | |
J | CE-C-SZ | SAE Flare Angle | Thermostatic Expansion Valve | €227.32 | |
J | CE-B-SZ | SAE Flare Angle | Thermostatic Expansion Valve | €270.44 | |
J | C-A-SZ | SAE Flare Angle | Thermostatic Expansion Valve | €212.64 | |
J | C-AA-SZ | SAE Flare Angle | Thermostatic Expansion Valve | €214.39 | |
K | CEAVW | SAE Flare Angle | Thermostatic Expansion Valve | €248.93 | |
L | OVE15VX100 | Straight Through Solder | Thermostatic Expansion Valve | €608.90 | |
M | ECE-D-ZX200 | Straight Through Solder | Thermostatic Expansion Valve | €261.03 | |
L | OVE20VX100 | Straight Through Solder | Thermostatic Expansion Valve | €608.90 | |
L | OVE30VX100 | Straight Through Solder | Thermostatic Expansion Valve | €608.70 | |
L | OVE40VX100 | Straight Through Solder | Thermostatic Expansion Valve | €1,073.28 | |
N | EBSE8VX100 | Straight Through Solder | Thermostatic Expansion Valve | €426.26 | |
F | SCE-B-JW | Straight Through Solder | Thermostatic Expansion Valve | €342.96 | |
O | EC-AA-JW | Straight Through Solder | Thermostatic Expansion Valve | €266.59 | |
O | EC-A-JW | Straight Through Solder | Thermostatic Expansion Valve | €231.61 | |
O | EC-AA-SZ | Straight Through Solder | Thermostatic Expansion Valve | €266.57 | |
O | EC-A-SZ | Straight Through Solder | Thermostatic Expansion Valve | €222.98 | |
N | EBSE11VX100 | Straight Through Solder | Thermostatic Expansion Valve | €452.49 | |
N | EBSE15VX100 | Straight Through Solder | Thermostatic Expansion Valve | €533.54 |
Thermostatic Expansion Valves
Thermostatic expansion valves, often abbreviated as TXVs, TEVs or TX valves reduce refrigerant pressure from the condenser pressure to the evaporator pressure. These valves keep the evaporator active as they increase the flow of refrigerant at high capacity loads and reduce the flow at low capacity loads. Thermal expansion valves provide complete evaporation of liquid refrigerant in the evaporator, thus eliminating liquid slugging. Thermal expansion valves can tolerate variation in refrigerant charge, as they adapt the refrigerant flow for matching the heat load. These valves minimise coil starving & flood back problems by controlling accuracy.
Uses
Parker Thermostatic expansion valves are used for regulating the flow of liquid refrigerant into an evaporator in aerospace, fluid & gas handling, hydraulic, filtration, sealing, shielding and process control applications.
Working Mechanism
The high-pressure liquid refrigerant is held back from the condenser by the valve. The valve regulates how much refrigerant can enter the evaporator. The valve decreases the pressure, allowing the refrigerant to boil at decreased temperatures. As the refrigerant is exposed to more thermal energy while passing through the evaporator, it undergoes a complete phase change and becomes a saturated vapour while reaching the end of the evaporator coil. During this change, there is almost no temperature change due to latent heat. Instead, there is an increase in entropy and enthalpy. The refrigerant continues picking up thermal energy and after the phase change, it begins increasing the temperature, thus superheating the refrigerant vapour. This temperature is monitored by the sensing bulb of the expansion valve to control the refrigerant in the main body of the valve.
Features
- SC(E) Series valves are used in freezers, walk-in coolers, salad bars and ice machines. They feature brass body construction for excellent corrosion resistance. These valves have a balanced port design that maintains the refrigerant flow level in low ambient conditions. They are equipped with a removable inlet strainer for filtering contaminants out of hydraulic fluids. These thermostatic expansion valves utilise field adjustable superheat steam to minimise the risk of damage caused by carbonic acid corrosion or erosion.
- EBSE Series valves provide extended ODF connections for excellent control in both flow directions.
- Parker H / HC Series thermostatic expansion valves are ideal for use on heat pumps and air conditioning systems. These H / HC Series valves have a power element made of stainless steel for resisting corrosion on exposed surfaces and bleed ports for releasing pressure from the hydraulic system. HC valves are equipped with an internal check valve to protect equipment against backflow damage. These HC Series valves add an in-built, 5-ton check valve for R-407C, R-22 and R-410A heat pump applications, with either field-adjustable or factory-set superheat.
Installation
- Locate the adjustment needle on the thermostatic expansion valve and turn the adjustment needle one quarter anticlockwise, to decrease the temperature.
- Each quarter turn is equivalent to one degree.
- Turn the adjustment needle 90 degrees clockwise for each degree required, to increase the temperature.
Frequently Asked Questions
What happens if the superheat is too high?
If superheat gets too high, it can increase the heat of compression, thus increasing temperature at the discharge valves. If the temperature elevates beyond its safe operating range, it may cause damage to the compressor.
How to adjust thermostatic expansion valves?
These thermostatic expansion valves are not adjustable in the open or closed positions as these are modulating valves. Turning the adjustment stem, whether in the clockwise or anti-clockwise direction, only increases / decreases the superheat.
Where are thermostatic expansion valves used?
These thermostatic expansion valves are utilised in systems such as packaged air conditioners, industrial refrigeration plants, central air conditioners and high capacity split air conditioners.
We are here to help!
Looking for a part not listed here?
Explore More
- KEYSHAFT
- LCN
- SK PROFESSIONAL TOOLS
- STIEBEL ELTRON
- SANISURE
- Extra Long Drill Bits
- Step Drill Bits
- Deadbolt Locks
- Coiled Air Hose Assembly
- Continuous Flexing Cable
- LOC-LINE Male NPT Valves
- AKRO-MILS Nest & Stack Storage Containers, Plastic, 55 Lb
- CONDOR Cowhide Leather Blue/Gray Palm Gloves
- TRI-ARC Steel Rolling Ladder, With Handrails
- WATTS Valve Kits
- AIR SYSTEMS INTERNATIONAL Portable Cool-Air Series Pumps
- TEADIT NA1035 Compresed Full Face Cut Gaskets with Aramid Fiber/SBR Binder