raptor logo

Strictly Necessary Cookies

Always Active

These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.

In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.

Advertising

These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.

recommendations

These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.

Functional

These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.

analysis

These cookies help us improve our website by collecting and reporting information on how you use it.

LEESON Fan and Blower Duty Motors, Dripproof, Resilient Base


Marathon fan and blower motors are used in band saws, drill presses, ventilators, farm equipment and summer cooling fans. These motors feature permanently lubricated, double sealed bearings for a smooth movement & extended motor life.

Filter
StyleModelFrameFrame MaterialFull Load AmpsHPHzLength Less ShaftMotor DesignMotor Mounting PositionPrice (ex. VAT)
A
5KC36LN26
48Rolled Steel6.0/3.2-3.01/350/608.5"Capacitor-StartHorizontal€1,043.35
B
5KC36LN26X
48Rolled Steel6.0/3.2-3.01/350/608.5"Capacitor-StartHorizontal€562.71
C
5KC35JN7X
48Rolled Steel5.2/2.61/4608 1/16"Capacitor-StartHorizontal€361.58
D
5KC39QN3220X
48Rolled Steel8.2/3.9-4.11/2609.5"Capacitor-StartHorizontal€349.01
E
5KC36MN27X
48Rolled Steel8.6/4.31/2608.5"Capacitor-Start-€609.30
F
048S17D2042
48Rolled Steel5.71/4607.5"Split-Phase-€236.62
G
048S17D2104
48ZRolled Steel5.31/4607.75"Split-Phase-€247.71
H
5KCR49PN0098X
56Steel9.0-8.8/4.5-4.43/450/60-Capacitor-Start/Capacitor-RunAll Angle€987.89
I
5KC48UN6052
56Rolled Steel9.4/4.71/260-Capacitor-Start-€1,114.35
J
5KH39QN9405X
56-7.91/260---€454.75
K
5KH39QN9541T
56-11.43/460---€542.76
L
5KC46LN0158X
56-13.2/6.63/460---€643.31
M
5KH39QN9687
56Rolled Steel11.43/4608 13/16"Split-Phase-€619.65
N
5KC46LN0254X
56Rolled Steel13.2/6.63/4608.875"Capacitor-Start-€519.84
O
5KC49PN0164X
56Rolled Steel14.7/7.2-7.41609.437"Capacitor-StartHorizontal€730.57
P
5KC49PN0155
56Rolled Steel13.6/6.7-6.81/2609.437"Capacitor-StartHorizontal€678.07
Q
5KC39RN383X
56Rolled Steel13.4/6.7-6.616010"Capacitor-StartHorizontal€562.71
R
5KC46JN0002X
56Rolled Steel11.4/5.6-5.73/4609"Capacitor-StartHorizontal€695.08
S
5KC49PN6051
56Rolled Steel8.6/4.31/3609.437"Capacitor-StartHorizontal€780.85
T
5KC49PN6051X
56Rolled Steel8.6/4.31/3609.437"Capacitor-StartHorizontal€803.04
U
5KC36LN1X
56Rolled Steel6.0/3.2-3.01/350/608.437"Capacitor-StartHorizontal€576.03
V
5KC49GN0022X
56Rolled Steel8.6/4.1-4.31/2608.5"Capacitor-StartHorizontal€578.99
W
5KC38NN410X
56Rolled Steel10.0/4.9-5.03/4609.437"Capacitor-StartHorizontal€449.59
X
5KC46LN0149X
56Rolled Steel13.3/6.5-6.63/4608.875"Capacitor-StartHorizontal€696.56
Y
5KC49GN0001
56Rolled Steel8.8/4.2-4.41/2608.5"Capacitor-StartHorizontal€512.44
Z
5KH39QN9544X
56-4.51/260---€124.34
A1
5KCR49SN0012X
56HRolled Steel18.2/9.11.56010"Capacitor-StartHorizontal€970.88
B1
5KCR49SN0150X
56HRolled Steel16.4/8.4-8.21.56010"Capacitor-StartHorizontal€685.29
C1
5KCR49RN2148T
56HRolled Steel19.6/10.4-9.826010"Capacitor-StartHorizontal€890.30
D1
5KH39QN5524
56ZRolled Steel6.61/3607 11/16"Split-Phase-€356.42
E1
5KH39QN9697T
56Z-4.01/260---€143.16
F1
5KH36MN3127T
56Z-8.9/4.51/260---€601.17
G1
145TBDR5345
145TRolled Steel21/11.3-10.526011 15/16"Capacitor-StartHorizontal€868.11

Features

  • They feature dripproof enclosures to permit external air flow through the motor windings to keep it cool during continuous operation.
  • They offer a single-phase design and attain a maximum speed of 1800 rpm. They are mounted in either horizontal / vertical orientation for user convenience.
  • They come integrated with resilient ring mounts to keep the motor suspended for reduced vibration and noise produced during motor startup.
  • They are available in dripproof and open enclosures to permit the flow of external air over and around the motor windings to keep it cool and prevent the entry of debris

Standards and Approvals

  • CSA
  • CE
  • UL

Frequently Asked Questions

What are the uses of automatic thermal protectors?

Thermal protector is a device sensitive to increased motor temperature and protects the motor against overheating due to overload or failure to start. These units are available with either manual or automatic reset.

What is the difference between single and multi-speed motors?

A single-speed motor has a constant speed rating at which it runs when supplied with the pre-determined voltage and frequency. A multi-speed motor runs at more than one speed (depending on how the motor has been connected to the supply).

What is the type of mounting orientation in these motors?

The fan and blower motors can be mounted in a horizontal or vertical orientation for user convenience.