These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
LEESON Brakemotors, Three Phase, TEFC, C Face With Base
Leeson brake motors are used on conveyors, machine tools, speed reducers, door operators and hoists which require a quick stop. They offer braking as a safety measure when power is cut abruptly.
Style | Model | Enclosure | Frame | Full Load Amps | HP | Hz | Insulation Class | kW | Motor Thermal Protection | Price (ex. VAT) | |
---|---|---|---|---|---|---|---|---|---|---|---|
A | 114155 | TEFC | 56C | 2.8 / 1.4 | 3/4 | 60 | B | 0.56 | - | €1,596.31 | |
B | 119563 | TEFC | 56C | 3.2-3.2 / 1.6 | 1 | 60 | F | 0.75 | 9700K46 | €1,950.35 | |
C | 122248 | TEFC | 143TC | 3.2 / 1.6 | 1 | 60 | F | 0.75 | 9700K46-33 | €1,961.40 | |
D | 122249 | TEFC | 145TC | 4.8 / 2.4 | 1 1/2 / 1 | 50/60 | B | 1.12 / .75 | 9700K46-33 | €2,156.02 | |
E | 122250 | TEFC | 145TC | 6-5.8 / 2.9 | 2 / 1 1/2 | 50/60 | F | 1.49 / 1.12 | 9700K46 | €2,229.86 | |
F | 140639 | TEFC | 215TC | 26.8 / 13.4 | 10 / 7 1/2 | 50/60 | F | 7.50 / 5.60 | - | €5,653.00 | |
G | 110669 | TENV | C56C | 1.4-1.3 / .65 | 1/3 | 60 | B | .246 | - | €1,216.04 | |
H | 110670 | TENV | 56C | 2.0-1.8 / .9 | 1/2 | 60 | B | .37 | - | €1,364.42 | |
I | 110671 | TENV | 56C | 2.7-2.5 / 1.25 | 3/4 | 60 | F | .56 | - | €1,596.31 |
Working Mechanism
- Brake motors use an electromagnetic field for powering and braking the motor.
- They function by pushing a magnetic pole rotor through the applied current.
- The poles of the stator (surrounding the rotor) apply force to turn the shaft.
- When static AC or DC current is injected into the unit, the poles of the stator become static and stop the rotor.
Features
- Leeson brake motors feature durable steel frame construction for structural rigidity and Polyrex EM lubrication to resist oil & water leakage at temperatures up to 40 degrees Celsius.
- They have a drive-end, C-Face endshield with rigid base mounting for quick installation.
- These NEMA Design B units offer premium Class B / F insulation for temperature control.
- The brakes of these models are fail-safe and spring-set, owing to dual voltage brake coils.
- These motors produce torque up to 10 hp at 50 / 60Hz power supply.
- They come with a TEFC / TENV enclosure to ensure protection from dust, water and air-borne contaminants.
- These triple-phase units have a power Off manual release for user convenience in case of a power failure. The load is automatically stopped when power is turned Off.
- They offer continuous duty operation at speeds up to 1800 rpm.
Standards and Approvals
- NEMA
- IEC
Frequently Asked Questions
What is the difference between single, double and triple-phase motors?
- Single-phase motor: Electricity flows through a single conductor.
- Double-phase motor: Electricity flows through 4-wire conductors (2 for each phase).
- Triple-phase motor: Electricity flows through 3 separate conductors.
What do Class B and F insulation mean?
These motors have Class B or F insulation for temperature control. Class B insulated motors can handle temperatures up to 130 degrees C and Class F motors can withstand a maximum temperature of 105 degrees C.
What is the difference between TENV and TEFC motors?
Totally enclosed non-ventilated (TENV) motors are designed without air openings and are ideal for applications where frequent sanitising or cleaning is required. TEFC (totally enclosed fan-cooled) motors come with an external fan to circulate outside air to the motor.
We are here to help!
Looking for a part not listed here?
Explore More
- ALLSOURCE
- K-FLEX USA
- KEYSHAFT
- PHILLOCRAFT
- WHEATON
- Fire Hoods
- Electric Hand Planers
- Ratcheting Wrenches
- General Turning Tools
- Exit Sign and Light Combinations
- ANSELL 11-800 Hyflex Nitrile Foam Coated Industrial Gloves
- PROTO Impact Socket, 8 Point, 3/8 Inch Drive, Imperial
- SUNDSTROM SAFETY Correction Lenses
- LOC-LINE 90 Degree Nozzles For 1/4 Inch Systems
- JOHN GUEST Metric Swivel Male Elbows, BSPT Thread, Acetal Black
- MARTIN SPROCKET TBF Type Roller Chain Couplings
- DBI-SALA Sleeves
- KIMBLE CHASE Tenbroeck Glass Tissue Grinders