These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
EATON HFD Series Motor Circuit Protection Circuit Breakers
Eaton C Series HFD type motor circuit protection circuit breakers are ideal for commercial / industrial applications to protect motors, transformers and other electrical equipment from overload and short circuit conditions. They are used in motor control centres, switchboards and panels.
Style | Model | Price (ex. VAT) | |
---|---|---|---|
A | HFDMP3080JLA02 | €7,900.13 | |
A | HFDMP3100JLA02 | €7,900.13 |
Features
- They feature F-frames for enhanced thermal endurance and flexibility while installing them.
- These MCCBs have a magnetic trip to protect from short circuits.
- They offer 1A-1B rear with a left pigtail for ease of installation.
- These three pole MCCBs have line & load protection for enhanced motor protection.
Standards and Approvals
- CSA
- IEC
Frequently Asked Questions
How do I install these MCCBs?
- Before installing the circuit breaker, ensure turning off the power to the circuit you'll be working for safety and preventing damage to the equipment.
- Remove the panel cover to access the circuit breaker. This will typically require the use of a screwdriver or other tool.
- Mount the circuit breaker in the appropriate slot in the panel. Make sure to align the breaker's mounting tabs with the panel's slots. Secure the circuit breaker in place using the screws provided.
- Connect the wires to the circuit breaker. This may require stripping the wire insulation and using wire nuts or other connectors.
- Once the circuit breaker is installed and wired, turn the power back on and test the circuit to ensure that the breaker is functioning correctly.
How do I clean and maintain these Eaton C Series HFD type MCCBs?
- Before starting any maintenance work, turn off the power supply to the MCCB to avoid any electrical shock.
- Remove the cover of the MCCB carefully and gently to avoid any damage to the internal components.
- Use a soft brush or a lint-free cloth to clean the contacts of the MCCB. Make sure to remove any dirt or debris that may have accumulated on the contacts.
- Inspect the components of the MCCB for any signs of wear and tear, cracks or damage. If you notice any damage, replace the component immediately.
- Apply a small amount of lubricant to the moving parts of the MCCB to ensure smooth functioning.
What safety precautions should be taken while installing these F-frame MCCBs?
- The first step is to determine the voltage of your electrical system. The MCCB must be rated for the same voltage as your system.
- Determine the load current of your equipment by calculating the total current that flows through the circuit.
- Determine the maximum fault current of your electrical system.
- Determine the type of protection you require for your equipment, such as overload, short-circuit or both to choose an MCCB with the appropriate trip curve.
- Choose an MCCB from a reputable brand that meets international standards and has a good track record.
We are here to help!
Looking for a part not listed here?
Popular Search Queries
- Solenoid Valve Coils
- Cutting Blades
- Thermal Expansion Valve
- Hose Whip Check
- Battery Powered Hydraulic Pump
- Gas Cylinder Storage
- Spark Proof Centrifugal Blower
- Breathing Air Cascade System
- Portable Carbon Monoxide Detector
- Granite Surface Plate
- Lay Flat Plastic Ducting
- Hydraulic Pump Mounting Bracket
Explore More
- GEARWRENCH
- KEYSHAFT
- SPERRY INSTRUMENTS
- MSI
- RADNOR
- Steel Strapping
- Twist Lock Receptacles
- Intake Louvers
- Stretch Wrap Machine Accessories
- Chain Saw Accessories
- DESTACO 89R Series Pneumatic Swing Clamp Arms
- DESTACO 8021, 8071 Series Pneumatic Toggle Clamps
- OIL SAFE Mini Spout Lids
- RINGERS GLOVES R327 Extrication Gloves
- BENCHPRO 50 Inch Width Task Light Frame
- WESTWARD Wall Scraper
- VERMONT GAGE NoGo Standard Thread Plug Gages, 1-8 Unc
- VERMONT GAGE NoGo Standard Thread Plug Gages, 2 7/8-8 Thread
- DAYTON Vibration Mount Kits