EATON Danfoss RV10-10 Series Pressure Control Valves
raptor logo

Strictly Necessary Cookies

Always Active

These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.

In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.

Advertising

These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.

recommendations

These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.

Functional

These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.

analysis

These cookies help us improve our website by collecting and reporting information on how you use it.

We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.

EATON Danfoss RV10-10 Series Pressure Control Valves


Eaton Danfoss RV10-10 Series pressure control valves are ideal for controlling the overpressure of flowing fluids and protecting pumps in pneumatic and hydraulic systems. They are ideal for refuse haulers, harvesters and industrial applications.

Filter
StyleModelPrice (ex. VAT)
A
02-113064
€82.56
B
02-164521
€99.09
C
02-164508
€88.82
D
02-201097
€574.38

Working Mechanism

  • The spool moves to open the relief valve when the pressure of the fluid entering the valve is greater than the relief valve's set pressure, allowing the fluid to bypass the valve and return to the reservoir. By doing this, the system's components are prevented by pressure spikes.
  • The spring contracts as the fluid pressure inside the valve rises, moving the spool and reducing the fluid flow, resulting in a reduced pressure downstream of the valve.
  • The check valve works by using a ball or disc that presses into a seat by the pressure of the fluid.

Frequently Asked Questions

What is the recommended filtration level of these pressure control valves?

They comply with the ISO filtration cleanliness code of 18/16/13 to prevent contaminants from entering the valve.

What is the maximum working pressure of Eaton Danfoss RV10-10 Series pressure control valves?

70 bar.

What is the maximum flow rate of these pressure control valves?

38 litres per minute.