These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
EATON CND Series Electronic Molded Case Circuit Breakers, NG Frame
Eaton CND Series electronic moulded case circuit breakers (MCCBs) are used in low-voltage electrical systems to protect against overloads and short circuits. These circuit breakers feature electronic trip units that provide protection and monitoring capabilities.
Style | Model | Price (ex. VAT) | |
---|---|---|---|
A | CND312T32W | - | RFQ
|
A | CND3800T57XW | €52,876.24 | |
A | CND3800T106W | €67,437.80 | |
A | CND3800T36W | €12,099.89 | |
A | CND312T76XW | €85,304.79 | |
A | CND3800T107XW | €61,474.81 | |
A | CND3800T106XW | €64,901.06 | |
A | CND3800T52WPN | €49,680.61 | |
A | CND3800T52W | €47,308.58 | |
A | CND3800T107W | €64,066.45 | |
A | CND3800T35W | €94,353.61 | |
A | CND3800T52WZGP | €50,010.05 | |
A | CND3800T56WZGP | €63,901.74 | |
A | CND3800T33W | €73,708.26 | |
A | CND3800T56WPN | €63,572.28 | |
A | CND312T77XW | €75,915.56 | |
A | CND3800T57WZGP | €58,092.48 | |
A | CND3800T56XWPN | €61,002.60 | |
A | CND3800T56W | €61,255.18 | |
A | CND3800T57W | €55,445.92 | |
A | CND3800T57XWZGP | €55,500.82 | |
A | CND3800T56XWZGP | €61,354.00 | |
A | CND3800T57WPN | €57,708.12 | |
A | CND3800T76W | €67,503.68 | |
A | CND3800T77W | €60,376.64 | |
A | CND3800T56XW | €58,696.46 | |
A | CND3800T57XWPN | €55,160.40 | |
A | CND3800T76XW | €64,923.02 | |
B | CND412T32W | €191,123.16 | |
A | CND3800T32W | €86,117.44 | |
A | CND312T57XWZGP | €72,050.06 | |
A | CND312T33W | - | RFQ
|
A | CND312T56W | €79,726.17 | |
C | CND312T35W | - | RFQ
|
A | CND312T106W | €93,486.08 | |
A | CND312T52WPN | €68,030.79 | |
A | CND312T107XW | €80,670.59 | |
A | CND312T52WZGP | €68,360.26 | |
A | CND212T33WP08Z04 | €78,474.28 | |
A | CND212T33W | €75,102.93 | |
A | CND312T56XW | €77,024.71 | |
A | CND312T56WZG | €81,845.60 | |
A | CND312T56WPN | €82,076.21 | |
A | CND312T106XW | €90,784.61 | |
A | CND312T107W | €83,361.08 | |
A | CND312T52W | €65,702.71 | |
A | CND312T56XWZG | €79,166.12 | |
A | CND312T36W | - | RFQ
|
A | CND312T57WPN | €74,367.16 | |
A | CND312T56XWPN | €79,396.71 | |
A | CND312T56XWZGP | €79,759.11 | |
A | CND312T57XWZG | €71,479.00 | |
A | CND312T57XW | €69,348.60 | |
D | CND312T76W | €87,995.28 | |
A | CND312T77W | €78,606.04 | |
A | CND312T56WZGP | €82,438.62 | |
A | CND312T57W | €72,039.08 | |
A | CND312T57WZG | €74,158.51 | |
A | CND312T57WZGP | €74,751.53 | |
A | CND312T57XWPN | €71,709.62 | |
A | CND3800T77XW | €57,817.95 |
Features
- They have a moulded case construction, which provides durability and protection against mechanical damage.
- These CND Series electronic moulded case circuit breakers have amperage ratings up to 1200A.
- They feature three pole configuration for controlling multiple connections simultaneously.
- These moulded case circuit breakers are equipped with electronic LSIG trip units to prevent a long time over current.
- They further feature zone selective interlock communication to prevent unintended tripping of downstream breakers when upstream breaker trips.
Standards and Approvals
- UL
- HACR
Frequently Asked Questions
How does an electronic LSIG trip unit work in MCCBs?
- The electronic LSIG trip unit continuously monitors the current flowing through the circuit breaker and trips the breaker if an overcurrent condition is detected.
- The unit uses microprocessors and algorithms to accurately determine the current magnitude & duration and to provide selective coordination with other devices in the electrical system.
What are the interrupt ratings of these circuit breakers?
- 85kAIC at 240VAC
- 50kAIC at 480VAC
We are here to help!
Looking for a part not listed here?
Explore More
- ACCURATE MANUFACTURED PRODUCTS GROUP
- FEBCO
- KEYSHAFT
- STA-KON
- VIKAN
- Hazardous Location Control Station Accessories
- Jobsite Boxes
- Chemical Resistant and Disposable Coveralls
- PA System Speakers
- Boiler Feed Pump
- MEMPHIS GLOVE Ninja BNF Work Gloves, 15 Gauge, Coated Palm And Fingertips With Dots
- 3M V9 Series Integrated Protective Eyewears
- VIEGA PROPRESS Reducers, Stainless Steel, Press x FTG, FKM
- JOHN GUEST Tube to Hose Stems, Acetal Gray
- NOTRAX MD Ramp System Nitrile Dry Area Mattings
- SPEARS VALVES CPVC Schedule 80 Fitting Female Adapters, Socket x Fipt
- ABLOY Deadbolt Locks
- FULHAM Electronic Fluorescent Ballasts
- INGERSOLL-RAND Rotary Screw Electric Air Compressors