These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
DAYTON Shutter Mount Exhaust Fans
Dayton shutter mount exhaust fans improve air circulation and remove pollutants in schools, storage facilities, factories and light manufacturing & assembly areas. These fans help maintain air quality and control temperature & humidity levels, with adjustable shutters ensuring efficient operati...on.Read more
Style | Model | Blade Dia. | Blade Material | Cfm @ 0.000-in. Sp | Cfm @ 0.125-in. Sp | Cfm @ 0.250-in. Sp | Full Load Amps | Height | Max. Depth | Price (ex. VAT) | |
---|---|---|---|---|---|---|---|---|---|---|---|
A | 484X39 | - | - | - | - | - | - | - | - | €239.23 | |
B | 484X42 | - | - | - | - | - | - | - | - | €403.59 | |
B | 484X44 | - | - | - | - | - | - | - | - | €421.59 | |
C | 484X36 | - | - | - | - | - | - | - | - | €137.29 | |
B | 484X43 | - | - | - | - | - | - | - | - | €406.40 | |
B | 484X48 | - | - | - | - | - | - | - | - | €778.37 | |
B | 484X46 | - | - | - | - | - | - | - | - | €442.42 | |
D | 484X38 | - | - | - | - | - | - | - | - | €167.13 | |
E | 484X49 | - | - | - | - | - | - | - | - | €560.84 | |
B | 484X41 | - | - | - | - | - | - | - | - | €384.13 | |
F | 484X37 | 10" | Aluminum | 600 CFM | 355 CFM | 240 CFM | 0.55A | 13-1/8" | 8" | €160.56 | |
G | 484X47 | 24" | Aluminum | 4600 CFM | 3040 CFM | 2260 CFM | 3.3A | 27-1/8" | 15" | €493.11 | |
E | 484X50 | 36" | Galvanized Steel | 8225 CFM | 6485 CFM | 2625 CFM | 6A | 39-1/8" | 17" | €743.73 |
Working Mechanism
- Shutter mount exhaust fans operate by creating a suction force inside a building by rotating fan blades powered by an electric motor. The shutter assembly is placed on the exhaust side of the fan, which is installed on an exterior wall.
- When the switch is turned on, the motor begins turning the fan's blades, drawing air in through the open shutters and pushing it out the open door. The indoor air quality is improved by this ventilation process, which helps remove stale air, moisture, odours, and contaminants from the building.
- The shutters automatically close when the fan is turned off to stop backdrafts and the entry of outside elements. Shutter mount exhaust fans can have their operation managed manually or remotely using switches or control panels.
Features
- These Dayton shutter mount exhaust fans have blades made of aluminium / steel for structural rigidity & corrosion resistance.
- They feature ball bearings for low rotational friction and Class B insulated, totally enclosed air-over enclosures for added safety.
- These Dayton shutter mount exhaust fans allow vertical mounting for easy installation.
- They deliver speeds up to 1550 rpm and can withstand a maximum temperature of 104 degrees F.
- These fans are available in 1/2, 1/3 and 1/25 hp variants.
Standards and Approvals
- UL
- cUL
- OSHA
Frequently Asked Questions
What is the voltage rating of these Dayton shutter mount exhaust fans?
They have a voltage rating of 115VAC at 60 Hz.
What is the maximum air flow rate of these shutter mount exhaust fans?
They offer air flow rates up to 8860 cfm.
How do I maintain a shutter mount exhaust fan?
Regular maintenance involves cleaning the fan blades and shutters to remove dust and debris. It's also important to check and replace any worn-out parts, such as the motor or belts, as needed.
We are here to help!
Looking for a part not listed here?
Explore More
- KANT-TWIST
- KEYSHAFT
- MOLDED FIBERGLASS
- NEWSTRIPE
- GASTEC
- Mobile Workbenches
- Air Powered Hydraulic Pumps
- Infrared Thermometer and Imager Accessories
- Parting and Grooving Tools
- Door Locks
- FERNCO No Hub Couplings
- CONDOR General Purpose Gloves, Yellow/Black, Abrasion Level 3
- TRI-ARC Heavy-Duty Grip Strut Forward Descent Safety Angle Rolling Ladders
- DESTACO 330-M Series Pull Action Latch Clamps
- CAMLOCK FITTINGS Type B Female Cam And Groove Coupler, Male NPT Thread
- HOSE MASTER 1/2 Inch x 10 Feet Cryogenic Hose
- APPROVED VENDOR Piston Seal
- SMC VALVES Zzm Series Manifold Unit
- GRAINGER Street Elbows
- THERN Base Replacement Covers