These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
DAYTON Exhaust/supply Fan
Dayton exhaust / supply fans are ideal for regulating temperature and preventing the buildup of harmful fumes in factories, warehouses and commercial spaces. These fans contribute to a safer workplace, ensuring proper air circulation and removing pollutants, heat, and odours.
Style | Model | Bearing Type | Fan Rpm | Height | Max. Depth | Motor Hp | Motor Rpm | Number Of Blades | Operating Amps | Price (ex. VAT) | |
---|---|---|---|---|---|---|---|---|---|---|---|
A | 10E021 | Ball | 1725 | 16" | 14-1/16" | 1/4 | 1750 | 4 | 2.9/1.4 | €680.81 | |
B | 10E022 | Ball | 1725 | 20" | 12-13/16" | 1/4 | 1750 | 4 | 2.9/1.4 | €693.43 | |
B | 10E023 | Ball | 1725 | 20" | 13-7/16" | 1/3 | 1750 | 4 | 3.4/2.1 | €698.23 | |
C | 10E024 | Ball | 1725 | 22" | 13-7/16" | 1/3 | 1750 | 4 | 3.5/2.2 | €715.20 | |
D | 10E025 | Ball | 1725 | 24" | 14-1/4" | 1/3 | 1750 | 3 | 4.0/2.9 | €760.82 | |
E | 10E026 | Ball | 1075 | 28" | 14-7/8" | 1/2 | 1140 | 3 | 4.6/3.4 | €907.74 | |
A | 10E027 | Ball | 1725 | 16" | 14-1/16" | 1/4 | 1750 | 4 | 1.5-1.6/.85 | €1,054.93 | |
B | 10E028 | Ball | 1725 | 20" | 12-13/16" | 1/4 | 1750 | 4 | 1.5-1.6/.85 | €1,044.76 | |
B | 10E029 | Ball | 1725 | 20" | 13-7/16" | 1/3 | 1750 | 4 | 1.7-1.9/0.85 | €1,210.57 | |
F | 10E030 | Ball | 1725 | 22" | 13-7/16" | 1/3 | 1750 | 4 | 1.7-1.9/0.85 | €1,305.46 | |
D | 10E031 | Ball | 1725 | 24" | 14-1/4" | 1/3 | 1750 | 3 | 1.7-1.9/0.86 | €1,350.73 | |
E | 10E032 | Ball | 1140 | 28" | 14-7/8" | 1/2 | 1140 | 3 | 1.8-2.0/0.90 | €1,341.71 | |
G | 4YGA3 | Regreaseable Cast Pillow Block | - | 34" | 21-1/2" | - | - | 6 | - | €1,515.48 | |
G | 4YGA4 | Regreaseable Cast Pillow Block | - | 54" | 23-1/2" | - | - | 6 | - | €2,737.56 |
Working Mechanism
- Exhaust fans work by creating negative pressure within a space. The fan expels indoor air, pollutants and moisture, creating a vacuum that draws fresh air into the space from outside.
- Supply fans function by forcing air into a designated area, creating positive pressure. They introduce fresh outdoor air into the space, replacing stale or polluted indoor air.
Features
- They feature aluminium construction, ensuring durability and resistance to corrosion.
- These exhaust / supply fans provide ball bearings and regreaseable cast pillow block bearing options, enhancing reliability and facilitating ease of maintenance.
- They are equipped with efficient ball bearings, ensuring smooth and reliable fan operation with reduced friction for extended service life.
- These Dayton exhaust fans come with variable fan speeds, reaching up to 1725 RPM, providing flexibility to adapt to different ventilation requirements.
Frequently Asked Questions
How are Dayton exhaust fans powered?
A wall switch usually controls the fan and draws power from the 20A circuit that powers the bathroom lights and receptacles.
What factors should be considered when selecting Dayton exhaust / supply fans for a specific application?
Consider factors such as the size of the space, required airflow, noise levels and any specific ventilation needs.
How do you calculate Dayton exhaust fan capacity?
A general guideline is to have a minimum of 1 cubic foot per minute (CFM) for every square foot of room area. To find the square footage of your bathroom, simply multiply the length by the width.
We are here to help!
Looking for a part not listed here?
Popular Search Queries
Explore More
- ELKAY
- KELCH
- KEYSHAFT
- MOEN
- XTEND & CLIMB
- Hollow Wall and Wallboard Anchors
- Reflectors Replacement Lenses
- Cable Lockouts
- Work Coveralls
- Screwdriver Bits And Nutsetters
- ANSELL 04-644 Alphatec Comfortable Pvc Coated Gloves
- DESTACO 371-M Series Pull Action Latch Clamps
- CAMLOCK FITTINGS Type D Female Cam And Groove Coupler, Female NPT Thread
- GRAPHIC CONTROLS Chart Recorder Pens
- HUSQVARNA Concrete Grinder Voltage
- EVERPURE Filter Head Assembly
- KERN AND SOHN Precision Balances
- JOBOX StorAll Series Drawer Units, 13 Inch Tall
- EATON Z Series Crimp Hose Fittings