raptor logo

Strictly Necessary Cookies

Always Active

These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.

In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.

Advertising

These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.

recommendations

These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.

Functional

These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.

analysis

These cookies help us improve our website by collecting and reporting information on how you use it.

DAYTON Hazardous Location Exhaust Fans, Explosion Proof, 24 Inch


Dayton hazardous location exhaust fans prevent fires or explosions in chemical-processing plants, refineries and food-production facilities. They resist sparking to reduce the risk of the ignition while cooling areas with flammable gases. These fans are often used for cooling machinery in tight... spaces and busy areas of manufacturing plants, warehouses & shipping operations.Read more

Filter
StyleModelCfm @ 0.000-in. SpCfm @ 0.125-in. SpCfm @ 0.250-in. SpCfm @ 0.375-in. SpCfm @ 0.500-in. SpFull Load AmpsHeightInside Dia.Price (ex. VAT)
A
10E018
3837330526371970-1.8-1.6/.828.25"24-1/2"€1,889.45
A
10E016
3837330526371970-6/3.2-328.25"24-1/2"€1,873.22
B
10E004
566949464010296319067.4/3.9-3.728"-€1,916.03
B
10E006
566949464010296319061.8-2/128"-€1,995.74
C
10E017
566949464010296319067.4/3.9-3.728.25"24-1/2"€1,995.62
C
10E019
566949464010296319061.8-2/128.25"24-1/2"€1,719.00
D
10E005
6317585153144729411710.6/5.328"-€2,084.40
D
10E007
631758515314472941173.2-3/1.528"-€2,212.94
E
10E020
815375156804595749569.2/5-4.634.25"30-1/2"€2,344.56

Hazardous Location Exhaust Fans, Explosion Proof, 24 Inch

Dayton hazardous location fans remove harmful gases, fumes and flammable vapours from industrial environments. They feature spark-resistant aluminium propellers and 24-inch galvanised frames. These explosion proof fans are equipped with a 60Hz motor (1 or 3 phase) and ball bearings for high rotation speeds. They have Class B insulation and comply with UL, cUL, AMCA and CSA standards. Choose from a wide range of these hazardous location fans, available in ring and panel variants.
Raptor Supplies also offers 20 inch explosion proof fans.

Working Mechanism

  • Check the tightness of all the fasteners before turning on the fan.
  • Rotate the fan propeller with a hand before starting the fan to ensure smooth rotation.
  • Turn on the fan and check for any unusual noise.
  • Check for overloading while the motor is in operation.

Features

  • Dayton hazardous location exhaust fans have a powerful motor that drives the fan blades to move large volumes of air.
  • These 24 inch explosion proof exhaust fans consist of a guard enclosing the fan blades to prevent damages and injuries from accidental contact.
  • They feature galvanised steel construction for durability.
  • These industrial wall-mounted fans have a totally enclosed motor and spark-resistant aluminium propellers to prevent fire .
  • They feature high-performance ball bearings for a long life.

Standards and Approvals

  • UL
  • CUL
  • NEC

Frequently Asked Questions

How to install these exhaust fans?

  • Drill an appropriate-sized hole in the wall.
  • Mount the fan on a rigid frame to prevent movement during operation.
  • Maintain a 1/4 inch clearance around its perimeter.
  • Use fasteners in all pre-punched holes for secure connections.
  • Install remaining components like shutter and intake guard.

What are the power requirements of these exhaust fans?

Dayton offers a variety of hazardous location exhaust fans that can run on a single or three-phase power supply.

How do we keep these fans in good working conditions?

  • Conduct periodic inspections for cleaning the fan propeller and the housing unit.
  • Check for unusual noise while the fan is in operation.
  • Check for tightness of the fasteners at regular intervals.

How many blades do these exhaust fans have?

Dayton exhaust fans come in two-blade and three-blade variants.

How much power do these fans produce?

Dayton exhaust fans are equipped with 1/2, 1/3 or 3/4 HP motors for diverse uses.

We are here to help!

Looking for a part not listed here?