These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
CASH VALVE Cryogenic Pressure Regulator, For Cryogenic Converter, A-32 Series
Cash Valve A-32 Series cryogenic pressure reducing regulators are ideal for ensuring precise control of pressure in cryogenic systems, maintaining optimal conditions for converting gases into low-temperature liquids. They are used in liquefied natural gas (LNG) production, industrial gas manufa...cturing and cryogenic research. Read more
Style | Model | Inlet Size | Length | Outlet Size | Pressure Adjustment Range | Price (ex. VAT) | |
---|---|---|---|---|---|---|---|
A | 16856 (7337) | 1/4" | 3.25" | 1/4" | 75 to 175 psi | €432.91 | |
A | 16856 (4765) | 1/4" | 5.25" | 1/4" | 15 to 65 psi | €419.30 | |
A | 16856 (10661) | 1/4" | 6.25" | 1/4" | 100 to 250 psi | €419.30 | |
A | 22063 (7337) | 3/8" | 2.25" | 3/8" | 75 to 175 psi | €419.30 | |
A | 22063 (10661) | 3/8" | 4.25" | 3/8" | 100 to 250 psi | €447.24 | |
A | 22063 (4765) | 3/8" | 7.25" | 3/8" | 15 to 65 psi | €419.30 |
Working Mechanism
- It features an adjustable spring-loaded diaphragm that responds to changes in outlet pressure.
- When the outlet pressure increases, the diaphragm compresses the spring, reducing the flow of cryogenic fluid.
- If the outlet pressure decreases, the spring pushes the diaphragm to allow more fluid flow.
- This mechanism guarantees precise control of the outlet pressure, making it ideal for critical applications in cryogenic environments.
Features
- These cryogenic pressure reducing valves offer a pressure adjustment range of 15 to 250 psi, allowing precise control of pressure.
- They are equipped with an NPT connection type, ensuring secure and reliable attachment.
- These A-32 Series cryogenic safety relief valves can withstand a maximum initial pressure of 650 psi.
- They feature brass construction, ensuring sturdiness and corrosion resistance for reliable performance.
- These valves offer PTFE seal material to ensure compatibility with various substances and effective sealing properties.
Frequently Asked Questions
In what temperature ranges are these A-32 Series cryogenic pressure regulators designed to operate optimally?
These A-32 Series cryogenic pressure regulator is designed to operate within a temperature range of -320 to 150 degrees F.
How to install these cryogenic pressure reducing regulators?
- Choose a well-ventilated and accessible location for installing the regulator, ensuring compatibility with cryogenic conditions.
- Clear the installation area of obstructions, debris & hazards and consider protective barriers if needed.
- Confirm that the regulator matches the specific cryogenic fluid and pressure range of your application.
- Connect inlet and outlet lines with proper fittings and seals, securing leak-free connections.
- Install and vent any integrated pressure relief valve according to safety guidelines.
- Set the desired outlet pressure using the regulator's adjustment mechanism as per manufacturer's instructions.
- Conduct thorough leak checks and pressure tests post-installation to ensure proper functionality.
- Adhere to cryogenic safety regulations, using appropriate personal protective equipment during installation.
Can these cryogenic pressure regulators handle various types of cryogenic fluids?
Yes, these regulators are engineered to handle a wide range of cryogenic fluids, including liquefied gases like nitrogen, oxygen, helium and hydrogen.
We are here to help!
Looking for a part not listed here?
Popular Search Queries
Explore More
- KEYSHAFT
- TRAMEX
- YOUNG BROS. STAMP WORKS
- HDE
- PARTNERS BRAND
- Pin and Sleeve Devices
- Pavement Markers and Pavement Marking Tape
- Traffic Cones
- Wire Rope Swage Clevis Fittings
- Ceramic Fiber Insulation
- NORTH BY HONEYWELL NF11X Northflex Nylon Gloves, Red
- ULTRATECH Nylon Shell Palm Work Gloves
- CONDOR Cut-Resistant Sleeve, Kevlar, Knit Cuff, Black
- DIXON Tapes
- NOTRAX Diamond Plate Runners
- Cementex USA Metric Deep Wall Insulated Sockets, 3/8 Inch Square Drive
- GAST Vaccum Ejectors
- VESTIL VP Series Versa Rack Removable Post Kits