raptor logo

Strictly Necessary Cookies

Always Active

These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.

In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.

Advertising

These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.

recommendations

These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.

Functional

These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.

analysis

These cookies help us improve our website by collecting and reporting information on how you use it.

Hydronic Unit Heaters

Filter


Dayton hydronic unit heaters are designed for utilising non-potable hot water or steam produced by an indirect water heater or a boiler. These hydronic unit heaters are used in warehouses,...Read more

DAYTON -

Suspended Vertical Hydronic Wall & Ceiling Unit Heaters

Dayton suspended vertical hydronic heater units provide primary or supplementary heating by pushing and spreading the heated air. They are suspended from a wall or ceiling to spread the air evenly. These units store water, which is then heated by passing a current through rectangular coils and circulated with a maximum rate of 75 PSI. They feature a totally enclosed motor capable of producing a maximum power output of 3 HP. The heater units are ETL & ETLc listed and complies with OSHA standards for safe use. Choose from a wide range of unit heaters, available in single and three phase variants on Raptor Supplies.

StyleModelOutput @ 2 Psi SteamHeightDepthAir Flow RateMotor HpMounting HeightPhaseOutput @ 200 Deg. F WaterPrice (ex. VAT)
A5PV6341300 btuH10 3/4"18 1/4"595 CFM1/40 hp11 ft.122700 btuH€1,461.29
A5PV6665500 btuH11 1/8"21 1/4"989 CFM1/20 hp12 ft.139600 btuH€1,517.65
A5PV6880600 btuH11 5/8"21 1/4"1200 CFM1/20 hp15 ft.148400 btuH€1,869.28
A5PV54101800 btuH12 1/8"25 1/4"1490 CFM1/8 hp14 ft.168300 btuH€1,938.80
A5PV55124400 btuH12 3/4"25 1/4"1790 CFM167/1000 hp16 ft.183700 btuH€2,160.48
A5PV56152000 btuH13 5/8"29 1/2"2220 CFM167/1000 hp16 ft.1105200 btuH€2,322.05
A5PV57173000 btuH14 1/8"29 1/2"2620 CFM167/1000 hp18 ft.1118600 btuH€2,427.72
A5PV59249800 btuH5 1/8"37 1/2"4180 CFM1/4 hp20 ft.1180100 btuH€4,187.67
A5PV60283800 btuH15 1/4"37 1/2"4430 CFM1/2 hp21 ft.1205400 btuH€4,368.62
A5PV61333400 btuH16 3/4"37 1/2"5210 CFM3/4 hp24 ft.3242900 btuH€4,763.01
A5PV62386000 btuH17 5/8"37 1/2"6140 CFM3/4 hp28 ft.3280800 btuH€5,489.38
A5PV64496000 btuH17 1/4"42"8020 CFM1 1/2 hp29 ft.3368100 btuH€7,775.20
A5PV65585000 btuH20 3/4"42"9450 CFM1 1/2 hp34 ft.3431100 btuH€9,582.02
A5PV67705000 btuH24 1/4"42"11000 CFM3 hp38 ft.3519400 btuH€10,758.77
DAYTON -

Suspended Horizontal Hydronic Wall & Ceiling Unit Heaters

Dayton suspended horizontal hydronic heaters provide primary or supplementary heating by pushing and spreading the heated air. They are suspended from a wall or ceiling to spread the air evenly. These units store water which is then heated by passing a current through serpentine coils and circulated with a maximum rate of 150 PSI. They feature a totally enclosed motor which is capable of producing a maximum power output of 25W. They are ETL & ETLc listed and comply with OSHA standards for safe use. Choose from a wide range of these heaters, available in 245, 500, 580 and 850 CFM airflow ratings on Raptor Supplies.

StyleModelHeightDepthAir Flow RateMotor HpMounting HeightOutput @ 200 Deg. F WaterPowerAir Flow DirectionPrice (ex. VAT)
A5PV1916"7 3/4"500 CFM16 W8 ft.18400 btuH16 WHorizontal€1,126.85
A5PV2216"8 3/4"580 CFM25 W9 ft.24800 btuH25 WHorizontal€1,241.85
A5YH1816"3 3/4"245 CFM16 W8 ft.8030 btuH16 WHorizontal€1,046.29
A5PV2618 1/2"10 1/2"850 CFM1/20 hp9 ft.35900 btuH-Horizontal€1,499.88
DAYTON -

Horizontal Hydronic Unit Heaters, Water Or Steam Heating

Dayton horizontal hydronic unit heaters mount on walls for heating large areas, commercial and industrial spaces. These heaters feature threaded female NPT connections for the supply of water or steam to heat the air and have fans to push & spread the heated air horizontally. They come with adjustable louvres for controlling the direction of airflow. Selected models allow vertical mountingon the ceiling to push the heated air downward towards the floor. Choose from a wide range of these heaters, available in airflow speeds ranging from 395 to 5500 cfm.

StyleModelAir Flow DirectionOutput @ 2 Psi SteamHeightDepthAir Flow RateMax. Operating PressureMax. Operating Temp.Motor Enclosure DesignPrice (ex. VAT)
A1EBC1Horizontal240000 btuH30 1/4"14"3500 CFM150 psi366°FOpen Frame€4,309.10
A5PV32Horizontal180000 btuH29"14"2200 CFM75 psi320°FOpen Frame€3,076.77
A5YH19Horizontal120000 btuH25 1/4"14"1900 CFM75 psi320°FTotally Enclosed€2,345.85
A5PV53Horizontal96000 btuH24"14"1400 CFM75 psi320°FTotally Enclosed€2,227.38
A5PV52Horizontal96000 btuH24"14"1400 CFM75 psi320°FTotally Enclosed€2,093.62
A5PV51Horizontal84000 btuH24 1/4"12"1400 CFM75 psi320°FTotally Enclosed€1,911.95
A5PV50Horizontal72000 btuH21 3/4"11"1100 CFM75 psi320°FTotally Enclosed€1,827.41
A5PV49Horizontal72000 btuH21 3/4"11"1100 CFM75 psi320°FTotally Enclosed€1,693.66
A5PV48Horizontal60000 btuH20 1/2"11"900 CFM75 psi320°FTotally Enclosed€1,735.97
A5PV47Horizontal60000 btuH20 1/2"11"900 CFM75 psi320°FTotally Enclosed€1,625.64
A5PV46Horizontal48000 btuH20 1/4"11"750 CFM75 psi320°FTotally Enclosed€1,521.41
A5PV45Horizontal360000 btuH37 3/4"20"5500 CFM75 psi320°FOpen Frame€5,694.16
A5PV43Horizontal36000 btuH18"9"550 CFM75 psi320°FTotally Enclosed€1,307.53
A5PV35Horizontal204000 btuH29"14"2900 CFM75 psi320°FOpen Frame€3,500.26
A5PV34Horizontal204000 btuH29"14"2900 CFM75 psi320°FOpen Frame€3,414.19
A5PV33Horizontal180000 btuH29"14"2200 CFM75 psi320°FOpen Frame€3,258.35
A5PV31Horizontal18000 btuH15"9"395 CFM75 psi320°FTotally Enclosed€997.57
A1EBC2Horizontal280000 btuH30 1/4"18"4200 CFM150 psi366°FOpen Frame€4,780.26
A5PV30Horizontal156000 btuH27 3/4"14"2600 CFM75 psi320°FOpen Frame€3,067.40
A1EBC3Horizontal300000 btuH37 3/4"19"5000 CFM150 psi366°FOpen Frame€5,477.82
A1EBC4Horizontal360000 btuH37 3/4"20"5500 CFM150 psi366°FOpen Frame€5,915.79
A3DUF7Horizontal24000 btuH18"9"450 CFM150 psi355°FTotally Enclosed€1,244.54
A4NHG4Horizontal240000 btuH30 1/4"14"3500 CFM150 psi366°FOpen Frame€4,087.47
A4NHG5Horizontal280000 btuH30 1/4"18"4200 CFM150 psi366°FOpen Frame€4,493.56
A4NHG6Horizontal300000 btuH37 3/4"19"5000 CFM150 psi366°FOpen Frame€5,163.95

Hydronic Unit Heaters

Hydronic unit heaters utilize non-potable hot water or steam produced by a boiler, indirect water heater. Dayton heaters save floor space and are therefore commonly used in large areas like manufacturing facilities, warehouses and garages. These heaters are capable of pushing heated air horizontally and vertically and spread it across a larger area. Choose from a broad range of these Dayton hydronic heating units, available in 11000 cfm, 500 cfm, 450 cfm, 395 cfm and 245 cfm air flow options.

Working Mechanism

  • Hot water is produced by a central boiler for heating the water to the required temperature.
  • The hot water is then circulated through a series of heating coils / radiators within the unit heater.
  • The heat from the hot water is then transferred to the surrounding air through the heating coils.
  • A fan or blower inside the unit heater circulates the warm air into the heated space.
  • The cooled water then returns to the central boiler for reheating and the cycle repeats.
  • The temperature of the hot water is then controlled by adjusting the temperature setting on the central boiler and the amount of heat produced by the unit heater can be adjusted by controlling the flow of hot water through the heating coils or radiators.

Features

  • Dayton water & steam heated horizontal hydronic unit heaters come with fans to spread & push the heated air horizontally. These heaters have threaded female NPT connections to supply water / steam for heating the air and are equipped with adjustable louvres to control the direction of airflow. They can be mounted on walls for heating industrial spaces.
  • Dayton suspended vertical hydronic heaters are mounted on the ceiling or wall vertically to spread the air evenly. They feature a totally enclosed motor for protection from dust and have a maximum operating pressure of 75 PSI. These heater units are ETL & ETLc listed and comply with OSHA standards for safe & secure operations.
  • Dayton water heated horizontal hydronic unit heaters are suspended from a wall / ceiling horizontally to spread the air evenly. These units heat the stored water by passing a current through serpentine coils.

Frequently Asked Questions

What is the flow rate of Dayton hydronic unit heaters?

The flow rate of these heaters range from 245 to 11000 cfm.

What safety precautions should be taken when using hydronic unit heaters?

  • Get the system installed by a qualified technician.
  • Inspect the central boiler regularly and maintain it to ensure safe operation.

What is the role of a thermostat in hydronic unit heaters?

The thermostat controls the temperature of the hot water and the rate of heat transfer. The thermostat is set to the desired temperature and will turn the unit on and off as needed to maintain the required temperature.

We are here to help!

Looking for a part not listed here?