raptor logo

Strictly Necessary Cookies

Always Active

These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.

In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.

Advertising

These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.

recommendations

These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.

Functional

These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.

analysis

These cookies help us improve our website by collecting and reporting information on how you use it.

Flow Switches

22 - 39 of 39 Items (210 Products) Filter


<p>Flow switches detect fluid flow in hydraulic systems and prevent leaks. They are used in pumps in the water treatment, oil & gas and chemical industries.</p>
StyleModelHousing MaterialSwitch TypeConnection SizeConnection TypeMin. Flow RateMax. Flow RateMin. Ambient Temp.Max. PressurePrice
AFS-10798 25365BrassSPDT1/2"FNPT0.5 GPM20 GPM-20°F1000 psi€987.93
AFS-10798 25366Epoxy, Stainless Steel, VitonSPDT1/2"FNPT0.5 GPM20 GPM-20°F1000 psi€1,587.91
MCDONNELL & MILLER -

Spdt Snap Switch Flow Switches

StyleModelConnection SizeHousing MaterialSwitch TypeConnection TypeMax. Flow RateMin. Ambient Temp.Max. PressureVoltage
AFS2501"Stainless SteelSPDT Snap SwitchNPT-32°F160 psi120/240V AC
RFQ
AFS4-3T3/4", 1"Stainless SteelSPDT Snap SwitchNPT27 GPM32°F160 psi120/240V AC
RFQ
DAYTON -

Spst Flow Switches

StyleModelHousing MaterialConnection SizeConnection TypeMax. PressureVoltageEnclosure RatingSwitch TypeFor Pipe SizePrice
AV10Brass1/2"MNPT1000 psig, 2000 psig24V DC/120V ACNEMA 4XSPST1/2", 2"€163.43
B1DGZ7PVC1"FNPT150 psi115V ACNEMA 1SPST-€658.88
JOHNSON CONTROLS -

F261 Series Standard Model Flow Switches

StyleModelHousing MaterialVoltageEnclosure RatingSwitch TypeConnection SizeConnection TypeFor Pipe SizeMin. Flow RatePrice
AF261KAH-V01CPlastic, Stainless Steel24-230VNEMA 3RSPDT1"NPT1", 2", 3", 6"2.5 GPM€344.81
AF261MAL-V01CStainless Steel4-120VNEMA 4SPDT1"NPT1", 2", 3", 6"2.5 GPM€504.76
BF261MAH-V01CStainless Steel24-230VNEMA 4SPDT1"NPT1", 2", 3", 6"2.5 GPM€424.86
JOHNSON CONTROLS -

F261 Series Low-Flow Model Flow Switches

StyleModelHousing MaterialConnection SizeFor Pipe SizeEnclosure RatingSwitch TypeConnection TypeMin. Flow RateMax. Flow RatePrice
AF261MEH-V01CPlastic, Stainless Steel1/2"1/2"NEMA 4SPDTFNPT0.6 GPM17 GPM€554.73
AF261MFH-V01CStainless Steel3/4"3/4"NEMA 4SPDTFNPT0.6 GPM17 GPM€566.76
AF261KEH-V01CStainless Steel1/2"1/2"NEMA 3RSPDTFNPT0.6 GPM17 GPM€299.87
BF261KFH-V01CStainless Steel3/4"3/4"NEMA 3RSPDTFNPT0.6 GPM17 GPM€365.28
AF261KFH-V02CStainless Steel3/4"3/4"NEMA 3RSPDTFNPT0.6 GPM17 GPM€312.89
IFM -

Dc, Pnp Flow Switches

StyleModelMin. Flow RateMax. Flow RateHousing MaterialSwitch TypeConnection TypeSwitch EnclosureMin. Ambient Temp.Max. PressurePrice
ASBN3330.26 GPM6.6 GPMBrassDC, PNPNPTIP6732°F363 psi€641.57
BSBN3461.32 GPM26.4 GPMBrassDC, PNPNPTIP6732°F363 psi€678.24
StyleModelHousing MaterialSwitch TypeConnection SizeConnection TypeEnclosure RatingVoltage
AS19-324BSBrassDPDT1 1/4"NPTNEMA 4X90/264V AC
RFQ
AS19-324SSStainless SteelSilence Switch1 1/4"NPTNEMA 4X-
RFQ
SPEAKMAN -

Flow Switch Retro Kit

ModelItemPrice
RPG76-0043CE2DRB€2,349.58
MCDONNELL & MILLER -

Air Flow Switch

ModelItemPrice
AF1-SCH9NXF€962.58
JOHNSON CONTROLS -

Air Flow Switch, 2-1/8 Inch x 6-7/8 Inch Paddle Size, 16.0/8.0

ModelItemPrice
F262KDH-01CCR6AJW€378.22
DWYER INSTRUMENTS -

Flow Switch Brass

ModelItemPrice
V6EPB-B-S-LFCP4LMW€758.14
DWYER INSTRUMENTS -

Thermal Dispersion Flow Switch

ModelItemPrice
TDS112CP4LMX€1,036.45
DAYTON -

Flow Protector Booster Pump 230 V

ModelItemPrice
1DGZ8AA9HXM€756.21
DWYER INSTRUMENTS -

Level Switch Brass Body Spdt

ModelItemPrice
L6EPB-B-S-3-BCP4LMY€811.02
HONEYWELL -

Flow Switch Kit, Single Pack

ModelItemPrice
50053268-018/UBN9YWH€259.92
RFQ
HONEYWELL -

Air Flow Switch

ModelItemPrice
4074ETH/UBP2AFQ€139.17
RFQ
HONEYWELL -

Flow Switch, 1 Inch NPT Size

ModelItemPrice
FS4-3/UBP3GTN€337.81
RFQ
HONEYWELL -

Flow Switch, 1-1/4 Inch NPT Size

ModelItemPrice
FS7-4/UBP3GTR€788.49
RFQ
12

Flow Switches

Flow switches are primarily designed to monitor the air, steam or liquid flow and send signals to the pump for automatic ON / OFF switching with the rise and fall of water level; ideal for regulating water cooling equipment and water treatment or hydronic heating systems. Raptor Supplies offers a wide range of these liquid flow switches from brands like Bradley, Dwyer Instruments, Mcdonnell & Miller, Dayton, Johnson Controls, Gems Sensors and Taco. Gems Sensors flow switches uses 100-micron filtration technology and are less susceptible to clogging than other high-pressure inline flow switches. These units come equipped with one-piece magnetic composite piston which actuates the sealed reed switch when displaced by the pressure difference in fluid flow, thereby activating remote alarms or indicators. They are available in brass, polypropylene and stainless steel construction with a maximum pressure rating and flow rate of 1500 psi and 2 GPM, respectively. Taco industrial flow switches feature flow sensitivity adjustment mechanism for setting a wide adjustment range to start or stop an electronically operated device when flow / no-flow condition occurs. These low-flow switches come with a highly malleable EPDM seal providing anti-hardening, cracking and leakage properties and improving the performance in high-pressure applications such as chillers, boilers, heating systems and water systems. They are available in NEMA 1 and NEMA 4 rated enclosures providing protection against the ingress of foreign contaminants and are ideal for use with 1 - 8 inch (outer diameter) pipe sizes.

Working Mechanism

  • The flow switch contains a sensor element positioned within the fluid's flow route.
  • When fluid flows through the sensor element, it exerts a force or causes a pressure differential.
  • The flow switch has an adjustable actuation threshold, which is the predetermined flow rate or pressure level that must be exceeded for the switch to activate.
  • The force or pressure on the sensor element causes a mechanical or electrical response within the flow switch when the fluid flow reaches or exceeds the actuation threshold.
  • When a flow switch is activated, it produces an output signal that can be used to initiate control functions, such as activating an alarm, opening or closing valves or commencing a shutdown sequence.

Frequently Asked Questions

How can I maintain the accuracy of my flow switch over time?

  • Regularly clean the flow switch and inspect it for any signs of damage, corrosion or debris buildup.
  • Verify that the flow switch is properly aligned within the flow path to ensure accurate measurements.
  • Periodically calibrate the flow switch to verify its accuracy.
  • Take into account the properties of the fluid being monitored, such as viscosity or density, as these factors can impact the accuracy of the flow switch.
  • Be aware of the ambient conditions surrounding the flow switch. Consider protective enclosures for use in harsh environments.
  • Maintain a record of the flow switch's calibration dates, maintenance activities and any observed issues.

What is the difference between a flow switch and a pressure switch?

A flow switch measures the flow rate of media flowing through a process line, whereas a pressure switch measures the pressure within a process line, pipe or vessel.

How do I select the right flow switch for my application?

Consider factors like the type of fluid, flow rate, operating conditions (temperature or pressure) and pipe size.

Do these flow switches require regular maintenance?

These flow switches require minimal maintenance. However, periodic inspection and cleaning are necessary to ensure proper functioning.

Can I use these flow switches for both liquids and gases?

Yes, these flow switches can be used to detect the flow of both liquids and gases.

We are here to help!

Looking for a part not listed here?