These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
FANTECH Dampers
Control Damper
Dayton volume control dampers are used for regulating the volume of air passing through duct systems and provide a positive shutoff for modulating airflow in HVAC systems. These units have 16 gauge galvanised steel construction to withstand high temperatures up to 180 degrees F and prevent damage in tough environments. They feature symmetrical opposed blade configuration to regulate airflow in either direction and have stainless steel bearings for smooth operation. Choose from an array of these control dampers, available in 6, 8, 10, 12 and 14 inch duct diameters.
Dayton volume control dampers are used for regulating the volume of air passing through duct systems and provide a positive shutoff for modulating airflow in HVAC systems. These units have 16 gauge galvanised steel construction to withstand high temperatures up to 180 degrees F and prevent damage in tough environments. They feature symmetrical opposed blade configuration to regulate airflow in either direction and have stainless steel bearings for smooth operation. Choose from an array of these control dampers, available in 6, 8, 10, 12 and 14 inch duct diameters.
Style | Model | Price (ex. VAT) | |
---|---|---|---|
A | MD4-ES24VK | €230.24 | |
A | MD5-ES24VK | €230.24 | |
A | MD6-ES24VK | €230.24 |
Bypass Dampers
Control Dampers
Barometric Dampers
Style | Model | Price (ex. VAT) | |
---|---|---|---|
A | 7"MG1 | €227.34 | |
B | 16"M+MG2 | €1,166.13 | |
C | 4"RC | €102.26 | |
C | 9"RC | €197.95 | |
C | 8"RC | €165.34 | |
C | 7"RC | €135.48 | |
C | 5"RC | €90.81 | |
D | 6"M | €176.21 | |
B | 12"M+MG2 | €643.99 | |
B | 18"M+MG2 | €1,549.06 | |
A | 4"MG1 | €187.12 | |
B | 10"M+MG2 | €561.59 | |
B | 24"M+MG2 | €2,254.15 | |
B | 20"M+MG2 | €1,849.29 | |
B | 14"M+MG2 | €945.93 | |
E | 6"RC/BT | €190.91 | |
A | 6"MG1 | €213.21 | |
A | 5"MG1 | €231.51 | |
A | 8"MG1 | €293.72 | |
C | 6"RC | €97.37 |
Control Dampers
Style | Model | Price (ex. VAT) | |
---|---|---|---|
A | 50B924 | €559.20 | |
A | 859-09-6001-5 | €509.75 |
Duct Start/Take Off Collar
Round Dampers
Style | Model | Price (ex. VAT) | |
---|---|---|---|
A | D690A1002/U | €208.72 | RFQ |
A | D690A1036/U | €246.72 | RFQ |
A | D690A1010/U | €216.57 | RFQ |
A | D690A1028/U | €223.97 | RFQ |
A | D690A1051/U | €313.98 | RFQ |
A | D690A1044/U | €299.39 | RFQ |
B | MARD6 | €428.35 | |
C | MARD8 | €444.57 |
Volume Control Dampers
Dayton square control dampers provide a positive shutoff & regulate the volume of air passing through duct systems. These dampers feature extruded aluminium / galvanised steel frame for preventing damage against highly abrasive environments. Selected models feature symmetrical opposed blade configuration for modulating airflow in either direction. Choose from an extensive range of these volume control dampers, available for 10, 12, 16, 18 & 24 inch duct widths.
Dayton square control dampers provide a positive shutoff & regulate the volume of air passing through duct systems. These dampers feature extruded aluminium / galvanised steel frame for preventing damage against highly abrasive environments. Selected models feature symmetrical opposed blade configuration for modulating airflow in either direction. Choose from an extensive range of these volume control dampers, available for 10, 12, 16, 18 & 24 inch duct widths.
EFD Series Dampers
Fire Dampers
We are here to help!
Looking for a part not listed here?
Explore More
- Cutting Tools
- Equipment
- Slings
- Air Movement
- Lab Diagnostics
- Jobber Length Drill Bits
- Special Purpose Tape Kits
- Freight Car Bolts
- Boring and Grooving Tool Holders
- Paint Shakers
- MAXXIMA Warning Light
- HUBBELL WIRING DEVICE-KELLEMS Receptacle With Isolated Grounds
- PROTO Spline, Combination, Non Slip Metric Ratcheting Combination Wrench
- BRADY Pipe Marker, Boiler Feed
- ZSI-FOSTER W900SS Pre-Cuts Channel, Short Slot
- PASS AND SEYMOUR Trademaster Series Self Grounding Single Pole Toggle Switches
- GENERAL PIPE CLEANERS Kinetic Water Ram Series Cones
- SPEARS VALVES PVC Black Schedule 40 Fitting 90 Deg. Street Elbows, Spigot x Socket
- EATON IQ Series Analyzers
- REGAL STI Spiral Point Taps, Plug, HSS, TiALN