These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimization cookies to test new features and designs on our website. The information collected helps us improve our website and customers' experience.
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
These cookies help us improve our website by collecting and reporting information on how you use it.
- Safety
- Confined Space Equipment
- Confined Space Ventilation Ducting
Confined Space Ventilation Ducting
Confined space ventilation ducts are designed for use with confined space fans for providing fresh air supply and ventilating hazardous gases & fumes from basements, manholes and
...Read moreStandard Ductings
Allegro standard ducting have lightweight and retractable design, intended for maximum air handling capabilities and are built for dual direction flow with minimum friction loss. They feature vinyl and polyester materials with PVC covering which make them suitable for use in rough and harsh climatic conditions. These ducts further feature non-collapsible design and a yellow with dark climate strip for perceivability at work and also meet ASTM 227 specifications. Choose from a broad range of these standard ducting, available in 760 and 791 CFM options.
Allegro standard ducting have lightweight and retractable design, intended for maximum air handling capabilities and are built for dual direction flow with minimum friction loss. They feature vinyl and polyester materials with PVC covering which make them suitable for use in rough and harsh climatic conditions. These ducts further feature non-collapsible design and a yellow with dark climate strip for perceivability at work and also meet ASTM 227 specifications. Choose from a broad range of these standard ducting, available in 760 and 791 CFM options.
Standard and Conductive Ductings, Hazardous Location
Style | Model | Length | Diameter | Color | Price (ex. VAT) | |
---|---|---|---|---|---|---|
A | SVH-CND86 | €90.68 | ||||
B | SVH-CND815 | €154.15 | ||||
A | SVHCND1215 | €294.71 | ||||
C | SVH-CND825 | €226.70 | ||||
A | SVHCND1225 | €358.18 |
Standard and Conductive Ductings, Non-Hazardous Location
Lay Flat Disposable Ductings
Ventilation Ducts, PVC, Vinyl Coated Polyester Construction
Americ ventilation ducts direct fumes & foul air outside and draws fresh air into enclosed spaces. They feature PVC, vinyl coated polyester construction to withstand UV-radiation, humidity & extreme environmental conditions and can easily connect to ventilator fans or blower lips for negative or positive airflow. Further, these UL-listed ducts have easy retractable Schafer duct hoses to handle large volumes of air at low pressures and can collapse into the conveniently attached carrying bags. They are integrated with quick connect couplers, reducing media spillage and are available in lengths of 15 & 25 inches.
Raptor Supplies also offers Americ Disposable Ventilation Duct that can be cut in the lengths as required.
Americ ventilation ducts direct fumes & foul air outside and draws fresh air into enclosed spaces. They feature PVC, vinyl coated polyester construction to withstand UV-radiation, humidity & extreme environmental conditions and can easily connect to ventilator fans or blower lips for negative or positive airflow. Further, these UL-listed ducts have easy retractable Schafer duct hoses to handle large volumes of air at low pressures and can collapse into the conveniently attached carrying bags. They are integrated with quick connect couplers, reducing media spillage and are available in lengths of 15 & 25 inches.
Raptor Supplies also offers Americ Disposable Ventilation Duct that can be cut in the lengths as required.
Style | Model | Length | Diameter | Construction | Price (ex. VAT) | |
---|---|---|---|---|---|---|
A | GAM-DS0815 | €113.94 | ||||
A | GAM-DS1215 | €137.16 | ||||
B | GAM-DS0825CB | €215.74 | ||||
A | GAM-DS1225 | €290.31 | ||||
A | GAM-DS0825 | €169.65 | ||||
B | GAM-DS1225CB | €294.41 | ||||
A | GAM-DS2025 | €488.43 |
Style | Model | Length | Diameter | Construction | Color | Price (ex. VAT) | |
---|---|---|---|---|---|---|---|
A | GAM-DDISP500 | €385.23 | |||||
A | GAM-DDISP500FR | €512.12 |
Ventilation Ducts
Style | Model | Length | Diameter | Construction | Color | Price (ex. VAT) | |
---|---|---|---|---|---|---|---|
A | FDT-21624046BR | €220.91 | |||||
B | FDT-1215CBB | €755.71 | |||||
A | FDT-30534005BB | €346.03 | |||||
A | FDT-1625BR | €664.18 | |||||
B | FDT-1225CBB | €1,224.83 | |||||
B | FDT-1625CBR | €1,462.66 | |||||
A | FDT-21624076BR | €346.32 |
Reinforced Duct
Style | Model | Price (ex. VAT) | |
---|---|---|---|
A | FDT-0825CR | €201.65 | RFQ |
A | FDT-1215CBB | €446.67 | RFQ |
A | FDT-1225CBB | €731.81 | RFQ |
A | FDT-1615CBR | €505.22 | RFQ |
A | FDT-1625CBR | €859.74 | RFQ |
B | FDT-081207BB | €245.02 | RFQ |
Statically Conductive EX Ductings
Style | Model | Design | Diameter | Item | Length | Temp. Range | Price (ex. VAT) | |
---|---|---|---|---|---|---|---|---|
A | 9500-15AEX | €238.18 | ||||||
A | 9500-25AEX | €333.23 | ||||||
A | 9550-15AEX | €516.19 | RFQ | |||||
A | 9550-25AEX | €891.28 | RFQ | |||||
A | 9600-15AEX | €1,277.88 | RFQ | |||||
A | 9600-25AEX | €1,304.29 | RFQ | |||||
A | 9500-15EX | €239.01 | ||||||
A | 9500-25EX | €332.39 | ||||||
A | 9550-15EX | €493.59 | ||||||
A | 9550-25EX | €825.98 | ||||||
A | 9600-15EX | €688.13 | ||||||
A | 9600-25EX | €1,132.81 | ||||||
A | 9650-15EX | €832.65 | ||||||
B | 9650-25EX | €1,366.26 |
Style | Model | Price (ex. VAT) | |
---|---|---|---|
A | FDT-1615BR | €217.92 | RFQ |
A | FDT-1625BR | €329.58 | RFQ |
A | FDT-21624046BR | €147.45 | RFQ |
A | FDT-21624076BR | €208.16 | RFQ |
A | FDT-30534005BB | €223.34 | RFQ |
A | FDT-30534010BB | €381.62 | RFQ |
Style | Model | Price (ex. VAT) | |
---|---|---|---|
A | FDT-12DISP100 | €96.49 | RFQ |
A | FDT-16DISP100 | €151.78 | RFQ |
Pressure Duct
Style | Model | Price (ex. VAT) | |
---|---|---|---|
A | FDT-1810MSR | €403.31 | RFQ |
B | FDT-185MSR | €234.18 | RFQ |
Quick Couple Canister
Quick Couple Long Canister
Style | Model | Price (ex. VAT) | |
---|---|---|---|
A | ED7004CL/DS | €361.03 | RFQ |
B | EF7004CL/DS | €988.75 | RFQ |
Vent Duct, 12 Inch Diameter, 33 Feet Length, Yellow
Model | Item | Price (ex. VAT) | |
---|---|---|---|
FDT-30534010BB | AF4EJZ | €599.42 |
Unreinforced Layflat Duct, 25 Feet Length
Model | Item | Price (ex. VAT) | |
---|---|---|---|
FDT-1625SME | CL6VQZ | €306.82 | RFQ |
Confined Space Ventilation Ducting
Ventilation ducts are designed for use with confined space fans for providing fresh air supply and ventilating hazardous gases & fumes from basements, manholes and chemical processing plants. Raptor Supplies offers a wide array of Allegro, Ecko, Americ, Ramfan and Air Systems International blower exhaust ducts featuring a flexible design for ensuring quick installation in tough-to-reach spaces. Allegro ventilation ducts feature a statically conductive design for discharging the static build-up and preventing accidental sparks in hazardous locations, and a neoprene coating for withstanding temperatures up to 250 degrees F. Ventilation ducts from Air Systems International are made of polyethylene / vinyl for maintaining structural rigidity and also facilitate ease-of-storage & maximum job-site portability. Choose from a wide range of these ducts available in diameters ranging from 8 to 26 inches.
Working Mechanism
- HVAC ducting is installed in voids above a suspended ceiling.
- The ducting is responsible for supplying and extracting air from occupied spaces below.
- Diffuser grilles are used to distribute the air into the room or extract air from the room.
- Fans or air handling units are used to draw or blow air through the ducts.
- The airflow is controlled and directed to achieve proper heating, ventilation, and air conditioning in the building.
Features
Allegro Statically Conductive Ducts:
- Allegro statically conductive ducts are lightweight, retractable ducts designed for maximum air handling and dual-direction flow with minimum friction loss.
- These ducting units feature single ply, constructed with vinyl and polyester materials and a neoprene coating which offer temperature resistance up to 250 degrees F.
- They are incorporated with expanded strong grounding wire at each end.
- These ASTM-approved ducts are rated to 1000000 OHMS or less, per square inch.
- They are available in 8, 12, 16 and 20-inch diameters.
Air Systems International Standard and Conductive Ducts :
- They feature a 3/4 HP electric motor with 115VAC, 11.2A and 60Hz power supply.
- These ducting units come with a GFI power cord for added safety.
- They have an aluminium non-sparking blower wheel to prevent sparks in hazardous environments.
- These ducts have a polyethylene fan housing for durability and corrosion resistance.
- They come with a powder coat tubular steel frame with dual handles for easy transportation and stability.
- These ducting units have moulded safety guards for protection during operation.
- They feature an 8-inch intake and exhaust flange for efficient airflow.
- These lightweight & portable ducts deliver a free air delivery of 1570 cfm.
Frequently Asked Questions
How long are these ducting units?
They are available in sizes ranging from 6 to 825 ft.
When does confined space ventilation matter?
Ventilation in confined spaces is always important. According to OSHA's confined space standard (1910.146 Permit Required Confined Spaces), no workers are permitted to enter a space if a gas detector detects an atmospheric hazard. Employees are also not permitted to enter a space until forced air ventilation has been used to eliminate atmospheric hazards and this ventilation must continue until all employees have left the workspace.
Are these ducts ideal for use in extreme environmental conditions?
Americ ventilation ducts are made of PVC, vinyl coated polyester and can withstand UV radiation, humidity and extreme environmental conditions. They can also be easily connected to ventilator fans or blower lips for negative or positive airflow.
How do I clean maintain confined space ventilation ducting?
- Perform visual inspections regularly to check for damage, wear, or blockages.
- Remove any accumulated debris, dust, or obstructions inside the ducting.
- Mix water with a mild ducting cleaner or detergent for a suitable cleaning solution.
- Use a soft brush or cloth to apply the cleaning solution to the interior surface of the ducting.
- Gently scrub the interior surface to remove dirt, grease or residues without causing damage.
- Thoroughly rinse the ducting with clean water to remove the cleaning solution and debris.
- Allow the ducting to air dry completely to prevent moisture buildup.
- Check seals, joints, and connections for wear or damage, and replace them as needed.
- Store the cleaned and dried ducting in a clean, dry area away from potential damage or contamination.
How to install confined space ventilation ducting?
- Prepare the work area by clearing obstacles and debris.
- Measure the length and width of the installation area and plan the ducting route.
- Gather all the necessary equipment for installation.
- Connect the sections of ducting using appropriate connectors and clamps.
- Position the ducting along the planned route and secure it with straps or hangers.
- Install the inlet and outlet components, such as grilles or diffusers, ensuring proper alignment.
- Seal the joints and connections using duct tape or other sealing methods.
- Test the system for proper airflow, functionality, and potential leaks or obstructions.
What are the safety precautions to consider while using confined space ventilation ducts?
It is important to ensure that the ducting is properly secured and does not obstruct pathways or create trip hazards. Regular inspection and maintenance should be conducted to identify any damage or wear and replace any worn-out components.
We are here to help!
Looking for a part not listed here?
Popular Search Queries
Explore More
- CPS PRODUCTS
- SURE MOTION
- KEYSHAFT
- FUSION TOOLS
- KETT TOOLS
- Glove Dispensers
- Recycled Trash Bags and Liners
- Shaft Collars
- Noise Control Accessories
- Stainless Steel Push Fit Pipe Fittings
- ASAHI Screens
- QUANTUM STORAGE SYSTEMS Black Epoxy Side And Back Ledges
- BALDOR / DODGE Split Tire, ES4M, Elastomeric Couplings
- AKRO-MILS 30220 Akrobins Plastic Storage Bins
- ALLEGRO SAFETY SpanBak Back Supports
- ALLEGRO SAFETY Tyvek Double Bib High Pressure Hard Hat Hoods, Deluxe